Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RCK LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of RCK LLC in 2647 N. DESIGN COURT, SANFORD, FL 32773 (NAICS 334510). OSHA activity number 341983724.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RCK LLC — free Get an email when a new federal OSHA severe-injury report for RCK LLC is published. One employer, no account, unsubscribe in one click.
Establishment
RCK LLC
Site address
2647 N. DESIGN COURT
City
SANFORD
State
FL
ZIP
32773
Mailing
2647 N. DESIGN COURT, SANFORD, FL 32773
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334510
Employees
24
Ownership type
A

6 citations on file for this inspection.

1910.212 A02

Serious Gravity 10 1 instance 2 exposed
Issued
May 5, 2017
Abate by
Jun 1, 2017
Penalty
Initial $5,070 · Current $5,070
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:  a) In the manufacturing area, employees were exposed to amputation hazards, in that, the Easy Load Solder Change Over Machine hood for the RPS Rhythm Slide Selective Soldering System was not affixed to the machine. This violation was observed on or about December 15, 2016.
Recent events (1)
  • — Z (S) $5070

1910.305 D02

Serious Gravity 5 1 instance 21 exposed
Issued
May 5, 2017
Penalty
Initial $3,622 · Current $3,622
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and/or were not dead front:  a) In the manufacturing area by the bathrooms, employees were exposed to electrical hazards from the dead front and trim of the breaker box that was removed. This violation was observed on or about December 15, 2016.
Recent events (1)
  • — Z (S) $3622

1910.1025 D02

Serious Gravity 5 1 instance 21 exposed
Issued
May 5, 2017
Abate by
Jun 1, 2017
Penalty
Initial $3,622 · Current $3,622
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level:  a) In the manufacturing area, the employer did not do an initial determination to determine if any employee may be exposed to lead. This violation was discovered on or about December 15, 2016.
Recent events (1)
  • — Z (S) $3622

1910.1025 H01

Serious Gravity 5 8 instances 21 exposed
Issued
May 5, 2017
Abate by
Jun 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:   a) On the MPM Momentum handle, 390.2um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016.   b) On the Board Load Hood handle of the RPS Rhythm Slide Selective Soldering System, 170.00um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016.  c) On the Right desk/table by the RPS Rhythm Slide Selective Soldering System, 130.00um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016.  d) On the mouse connected to the RPS Rhythm Slide Selective Soldering System, 97.05um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016.  e) On the Table surface by the SMT machine, 60.9um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016.  f) On the Left desk/table by the RPS Rhythm Slide Selective Soldering System, 36.355um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016.  g) On the start button connected to the RPS Rhythm Slide Selective Soldering System, 19.095um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016.  h) On the table in the eating area, 4.1645um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016.  i) On the Refrigerator handle, 1.255um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016.
Recent events (1)
  • — Z (S) $0

1910.1025 M01 I

Serious Gravity 5 1 instance 21 exposed
Issued
May 5, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(m)(1)(i): The employer did not comply with all the requirements of the Hazard Communication Standard for lead:  a) In the workplace, the employer did not have a Hazard Communication Program. This violation was discovered on or about December 15, 2016.
Recent events (1)
  • — Z (S) $0

1910.1025 L01 II

Serious Gravity 5 1 instance 21 exposed
Issued
May 5, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(l)(1)(ii): The employer did not train each employee who is subject to exposure to lead at or above the action level, or for whom the possibility of skin or eye irritation exists, in accordance with the requirements of 29 CFR 1910.1025:  a) In the workplace, employees were not provided with training regarding the lead in their work area. This violation was discovered on or about December 15, 2016.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341983724.