On , OSHA opened an unprogrammed Other safety inspection of TRI-STATE CONCRETE CONSTRUCTION INC. in E. ROBERTS RD., APPLE RIVER, IL 61001 (NAICS 238110). OSHA activity number 341988194.

Watch Tri-State Concrete Construction INC. — free Get an email when a new federal OSHA severe-injury report for Tri-State Concrete Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
E. ROBERTS RD.
City
APPLE RIVER
State
IL
ZIP
61001
Mailing
15712 KEYCITY LANE, PEOSTA, IA 52068
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
15
Ownership type
A

2 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 13, 2017
Abate by
Feb 28, 2017
Penalty
Initial $3,622 · Current $2,160 Reduced
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.    On or about September 23, 2016, an employee was exposed to electrical shock when the boom from the concrete pump he was operating came in contact with energized electrical lines. The employer failed to ensure the employee was adequately instructed in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3622

1926.600 A06 I

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 13, 2017
Abate by
Feb 28, 2017
Penalty
Initial $5,070 · Current $3,040 Reduced
29 CFR 1926.600(a)(6)(i): All equipment covered by this subpart shall comply with the following requirement when working or being moved in the vicinity of power lines or energized transmitters, except where electrical distribution and transmission lines have been deenergized and visibly grounded at point of work or where insulating barriers, not a part of or an attachment to the equipment or machinery, have been erected to prevent physical contact with the lines:    (i) For lines rated 50 kV or below, minimum clearance between the lines and any part of the crane or load shall be 10 feet.    On or about September 23, 2016, an employee was exposed to electrical shock when the boom from the concrete pump he was operating came in contact with energized electrical lines rated 50kV or below. The employer failed to ensure the employee was protected against electric shock by deenergizing/grounding the circuit, or guarding it effectively with insulation barriers, or by maintaining a distance of at least 10 feet.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).