APPLE RIVER, IL —
OSHA Inspection: TRI-STATE CONCRETE CONSTRUCTION INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of TRI-STATE CONCRETE CONSTRUCTION INC. in E. ROBERTS RD., APPLE RIVER, IL 61001 (NAICS 238110). OSHA activity number 341988194.
Where did this inspection happen?
- Establishment
- TRI-STATE CONCRETE CONSTRUCTION INC.
- Site address
- E. ROBERTS RD.
- City
- APPLE RIVER
- State
- IL
- ZIP
- 61001
- Mailing
- 15712 KEYCITY LANE, PEOSTA, IA 52068
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.21 B02
- Issued
- Feb 13, 2017
- Abate by
- Feb 28, 2017
- Penalty
- Initial $3,622 · Current $2,160 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. On or about September 23, 2016, an employee was exposed to electrical shock when the boom from the concrete pump he was operating came in contact with energized electrical lines. The employer failed to ensure the employee was adequately instructed in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $2160
- — Z (S) $3622
1926.600 A06 I
- Issued
- Feb 13, 2017
- Abate by
- Feb 28, 2017
- Penalty
- Initial $5,070 · Current $3,040 Reduced
General-duty citation text
29 CFR 1926.600(a)(6)(i): All equipment covered by this subpart shall comply with the following requirement when working or being moved in the vicinity of power lines or energized transmitters, except where electrical distribution and transmission lines have been deenergized and visibly grounded at point of work or where insulating barriers, not a part of or an attachment to the equipment or machinery, have been erected to prevent physical contact with the lines: (i) For lines rated 50 kV or below, minimum clearance between the lines and any part of the crane or load shall be 10 feet. On or about September 23, 2016, an employee was exposed to electrical shock when the boom from the concrete pump he was operating came in contact with energized electrical lines rated 50kV or below. The employer failed to ensure the employee was protected against electric shock by deenergizing/grounding the circuit, or guarding it effectively with insulation barriers, or by maintaining a distance of at least 10 feet. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $3040
- — Z (S) $5070
More inspections at Tri-State Concrete Construction INC.
View Tri-State Concrete Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341988194.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.