Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MEADVILLE FORGING COMPANY, L.P.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MEADVILLE FORGING COMPANY, L.P. in 440 MCCLELLAN ST., CAMBRIDGE SPRINGS, PA 16403 (NAICS 336399). OSHA activity number 341991487.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Meadville Forging Company, L.P. — free Get an email when a new federal OSHA severe-injury report for Meadville Forging Company, L.P. is published. One employer, no account, unsubscribe in one click.
Site address
440 MCCLELLAN ST.
City
CAMBRIDGE SPRINGS
State
PA
ZIP
16403
Mailing
15309 BALDWIN STREET EXT. P.O. BOX 459, MEADVILLE, PA 16335
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
71
Ownership type
A

4 citations on file for this inspection.

1910.37 A02

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 21, 2017
Abate by
Apr 14, 2017
Penalty
Initial $6,157 · Current $3,694 Reduced
29 CFR 1910.37(a)(2): Exit routes must be arranged so that employees will not have to travel toward a high hazard area, unless the path of travel is effectively shielded from the high hazard area by suitable partitions or other physical barriers:       a.) Meadville Forging Company, L.P., 440 McClellan St., Cambridge Springs, PA, Northeast corner exit of Maintenance area, on or about March 15th, 2017, and times prior thereto:  One oxygen cylinder and one acetylene cylinder were stored on a cylinder cart directly next to the exit door.
Recent events (2)
  • — I (S) $3694
  • — Z (S) $6157

1910.37 A03

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 21, 2017
Abate by
Apr 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level:      a.)  Meadville Forging Company, L.P., 440 McClellan St., Cambridge Springs, PA, Northeast exit of CNC Machining area, on or about December 22nd, 2016 and times prior thereto:  The Northeast exit door located in the CNC Machining area was obstructed by snow/ice which did not allow the door to be opened in the event of an emergency.        b.)  Meadville Forging Company, L.P., 440 McClellan St., Cambridge Springs, PA, "Chip removal" exit east side of building, on or about December 22nd, 2016 and times prior thereto: Directly outside of the exit door there was an approximate 6.5 inch curb which created a potential trip/fall hazard along the egress route.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Mar 21, 2017
Abate by
Apr 14, 2017
Penalty
Initial $6,157 · Current $0 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a.) Meadville Forging Company, L.P., 440 McClellan St., Cambridge Springs, PA, Northeast corner of Maintenance area, on or about March 15th, 2017, and times prior thereto:  Employees were potentially exposed to a fire/explosion hazard in that, one oxygen cylinder was stored directly next to one acetylene cylinder on a cylinder cart.  The valve protection caps were not affixed to either cylinder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6157

1910.106 E02 IV C

Other-than-serious 1 instance 3 exposed
Issued
Mar 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(2)(iv)(c): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), may be used only where there are no open flames or other sources of ignition within the possible path of vapor travel:    a.)  Meadville Forging Company, L.P., 440 McClellan St., Cambridge Springs, PA, Pressure washer area, on or about December 22nd, 2017, and times prior thereto:  Flammables including, but not limited to, gasoline were stored within 4 feet of potential ignition sources including, but not limited to, a Shark brand pressure washer.  Fueling operation of equipment occurred next to the pressure washer.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Meadville Forging Company, L.P.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341991487.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.