CLEARWATER, FL —
OSHA Inspection: MUNYAN RESTORATION, WATERPROOFING & PAINTING SERVICE, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MUNYAN RESTORATION, WATERPROOFING & PAINTING SERVICE, LLC in 100 PIERCE STREET, CLEARWATER, FL 33756 (NAICS 238320). OSHA activity number 341996346.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 100 PIERCE STREET
- City
- CLEARWATER
- State
- FL
- ZIP
- 33756
- Mailing
- 1175 GOULD STREET, CLEARWATER, FL 33756
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.1053 B13
- Issued
- Jan 5, 2017
- Penalty
- Initial $2,702 · Current $1,621 Reduced
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. At the jobsite, the top of a step ladder was used as a step by employees climbing on and off a swing stage scaffold, exposing employees to a 4 foot fall hazard, on or about 12/27/16.
Recent events (2)
- — I (S) $1621.2
- — Z (S) $2702
1926.451 D03 X
- Issued
- Jan 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(d)(3)(x): Single tiebacks were installed at an angle: a. On the roof, the single tieback used to support an outrigger was not installed in a parallel line with the beam of the outrigger, exposing employees to a fall hazard, on or about 12/27/16.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.451 D12 IV
- Issued
- Jan 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(d)(12)(iv): Clips shall be inspected and retightened to the manufacturer's recommendations at the start of each workshift thereafter: a. On the roof, the wire rope clips on the tiebacks supporting the swing stage scaffolding were not checked for the correct tightness before the start of the shift, exposing employees to a fall hazard, on or about 12/27/16.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.502 D11
- Issued
- Jan 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded: a. On the east side of the roof, chafing material was not provided for the lifelines employees were using while working from a swing stage scaffold, exposing the employees to a 30 foot fall hazard, on or about 12/27/16.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Munyan Restoration, Waterproofing & Painting Service, LLC
View Munyan Restoration, Waterproofing & Painting Service, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238320)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341996346.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.