OSHA Inspection: PENNSYLVANIA INSULATING GLASS CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PENNSYLVANIA INSULATING GLASS CORP. in 6395 SR 103 NORTH, BLDG. 62, LEWISTOWN, PA 17044 (NAICS 327211). OSHA activity number 342000783.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pennsylvania Insulating Glass Corp. — free Get an email when a new federal OSHA severe-injury report for Pennsylvania Insulating Glass Corp. is published. One employer, no account, unsubscribe in one click.
Site address
6395 SR 103 NORTH, BLDG. 62
City
LEWISTOWN
State
PA
ZIP
17044
Mailing
6395 SR 103 NORTH, BLDG. 62, LEWISTOWN, PA 17044
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327211
Employees
24
Ownership type
A

9 citations on file for this inspection.

1910.133 A01

Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2017
Abate by
Jun 5, 2017
Penalty
Initial $2,897 · Current $2,500 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:    a)  6395 SR 103 North Building 62, Lewistown PA - On or about December 28, 2016 and times prior thereto, the employer failed to require employees to don appropriate eye protection when changing liquid propane (LPG) fuel cylinders on power industrial trucks exposing employees to burn hazards to the eyes.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $2500
  • — C (S) $2897
  • — Z (S) $2897

1910.132 D01

Serious Gravity 5 1 instance 24 exposed
Issued
May 9, 2017
Abate by
Jun 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  a)  6395 SR 103 North Building 62, Lewistown PA - On or about December 28, 2016 and times prior thereto, the employer did not perform a hazard assessment to evaluate the need for protective equipment to prevent employee exposure to eye injuries and hand/wrist injuries during tasks associated with changing LPG cylinders on forklifts, operating saws and handling sheets of glass.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 10 1 instance 24 exposed
Issued
May 9, 2017
Abate by
Jun 12, 2017
Penalty
Initial $5,070 · Current $4,307 Reduced
29 CFR 1910.147(c)(1):  The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a)  6395 SR 103 North Building 62, Lewistown PA -  On or about December 28, 2016 and times prior thereto, the employer failed to establish a Lock out/Tag out program with procedures for the control of energy, periodic inspections and training to ensure employees were protected before starting servicing or maintenance on machines or equipment.  Employees were exposed to caught-in and struck-by hazards from electrical, hydraulic and mechanical energy sources.    Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (3)
  • — F (S) $4307
  • — C (S) $5070
  • — Z (S) $5070

1910.178 L01 I

Serious Gravity 5 1 instance 24 exposed
Issued
May 9, 2017
Abate by
Jun 12, 2017
Penalty
Initial $2,897 · Current $2,500 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph(l):    a)  6395 SR 103 North Building 62, Lewistown PA - On or about December 28, 2016 and times prior thereto, employees were allowed to operate a forklift at the site without having received formal instruction, including operator evaluation to determine the retention of the information.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $2500
  • — C (S) $2897
  • — Z (S) $2897

1910.303 F02

Other-than-serious 1 instance 5 exposed
Issued
May 9, 2017
Abate by
Jun 5, 2017
Penalty
Initial $2,897 · Current $0 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a)  Laminating Room - On or about December 28, 2016, the employer failed to ensure two (2) Square D 30A/600V electrical disconnects were legibly marked or located and arranged to identify what they controlled.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $0
  • — C (S) $2897
  • — Z (S) $2897

1904.29 A

Other-than-serious 1 instance 24 exposed
Issued
May 9, 2017
Abate by
Jun 12, 2017
Penalty
Initial $1,000 · Current $0 Reduced
29 CFR 1904.29(a): A log of all Work-Related Injuries and Illnesses (OSHA Form 300), and/or the Summary of Work-Related Injuries and Illnesses, (OSHA Form 300A) and/or the Injury and Illness Incident Report (OSHA Form 301) or equivalent forms were not kept by the establishment:    a)  6395 SR 103 North Building 62, Lewistown PA - On or about December 28, 2016, an OSHA Form 301 or equivalent was not completed for a work-related injury which occurred on December 14, 2016 and which resulted in lost time.    b)  6395 SR 103 North Building 62, Lewistown PA - On or about December 28, 2016, an OSHA 300 log was not kept by the employer for each recordable work-related injury.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $0
  • — C (O) $1000
  • — Z (O) $1000

1910.303 B01 II

Other-than-serious 1 instance 4 exposed
Issued
May 9, 2017
Abate by
Jun 5, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:  a)  Laminating Room;  Casso Solar Table - On or about December 28, 2016 the protective metal sleeve (conduit) was separated from the junction box exposing the internal conductors of a switch.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 4 exposed
Issued
May 9, 2017
Abate by
Jun 5, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for fixed wiring of a structure:  a)  Laminating Room;  Casso Solar Table - The employer substitutes flexible cords and/or cables for fixed wiring.  On or about December 28, 2016, an orange flexible cord plugged into a wall receptacle was hard wired into light fixtures underneath the table.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 4 exposed
Issued
May 9, 2017
Abate by
Jun 5, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to the joints or terminal screws:  a)  Laminating Room;  Casso Solar Table - On or about December 28, 2016, an orange flexible cord lacked strain relief where it was hard wired into light fixtures underneath the table.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.