CASCADE LOCKS, OR —
OSHA Inspection: ARMY CORPS OF ENGINEERS, BONNEVILLE DAM
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARMY CORPS OF ENGINEERS, BONNEVILLE DAM in BONNEVILLE DAM, CASCADE LOCKS, OR 97014 (NAICS 928110). OSHA activity number 342011566.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARMY CORPS OF ENGINEERS, BONNEVILLE DAM
- Site address
- BONNEVILLE DAM
- City
- CASCADE LOCKS
- State
- OR
- ZIP
- 97014
- Mailing
- PO BOX 150, CASCADE LOCKS, OR 97014
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 150
- Ownership type
- D
Citations
11 citations on file for this inspection.
1910.23 C01
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards. Power House #1 North end, Level 55- (a) The open sided floor above the Fish Screen Assembly area had a partial toe guard, leaving an unguarded 57" opening, exposing employees to struck-by hazards of falling objects.
Recent events (1)
- — Z (S) $0
1910.219 F03
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): All sprocket wheels and chains were not enclosed. Power House #1, Elevation 37 Bay 7- (a) The Cooling water strainer unit has an unguarded pulley sprocket, located approx. 18 inch off the floor, with an opening of 11 inches, exposing employees to serious injuries from rotating parts.
Recent events (1)
- — Z (S) $0
1910.304 G05
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Power House #2, Electrical Work Shop Side Gallery- (a) The Sure-Test Circuit Analyzer indicated an open ground condition on all five 110 volt receptacles tested, exposing worker to serious electrical hazards.
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) The 40 ton Hydraulic Press, SN#5865, Model PSS40, located in Power House #1 machine shop was not guarded to prevent flying parts. (b) The Dake Hydraulic Press, Model # 908150-4, SN#182308, located in B15B machine shop, was not guarded to prevent flying parts. (c) The SPX Hydraulic Press, located in the gear repair area, was not guarded to prevent flying parts. (d) The 40 ton Hydraulic Press, SN#5345, Model PSS40, located in Power House #2 machine shop was not guarded to prevent flying parts. (e) The horizontal band saw's, model 7020M, SN# 0605028, unused 10" portion of the saw blade was unguarded exposing operators to serious injuries. The Army Corps of Engineers was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1056021, notice number 1, item number 3 and was affirmed as a final order on 11/05/2015, with respect to a workplace located at Foster, OR 97345. The Army Corps of Engineers was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1056022, notice number 1, item number 2 and was affirmed as a final order on 11/05/2015, with respect to a workplace located at Blue River, OR 97413. The Army Corps of Engineers was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1056017, notice number 1, item number 1 and was affirmed as a final order on 11/05/2015, with respect to a workplace located at Mill City, OR 97360.
Recent events (1)
- — Z (R) $0
1910.215 B09
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Powerhouse #1, Elevation 65- (a) The Dayton 6" pedestal grinder's opening between the wheel periphery(s) and abrasive wheel measured 1" exposing operators to flying debris in the event of a wheel failure. The Army Corps of Engineers was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.215(b)(9), which was contained in OSHA inspection number 1051517, notice number 2, item number 1a and was affirmed as a final order on 10/20/2015, with respect to a workplace located at Oakridge, OR 97463. The Army Corps of Engineers was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.215(b)(9), which was contained in OSHA inspection number 941527, notice number 2, item number 3 and was affirmed as a final order on 12/11/2013, with respect to a workplace located at Rufus, OR 97050.
Recent events (1)
- — Z (R) $0
1910.219 C02 I
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Power House #1, Elevation 37 Bay 7- (a) The Cooling water pump's rotating shaft, located approx. 18 inches above the floor, has an exposed 2 1/2 inch opening, exposing employees to serious injuries. The Army Corps of Engineers was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.219(c)(2)(i), which was contained in OSHA inspection number 1056020, notice number 1, item number 3 and was affirmed as a final order on 11/05/2015, with respect to a workplace located at Mill City, OR 97360.
Recent events (1)
- — Z (R) $0
1910.253 B04 III
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. Crane Shop Building- (a) The oxygen and acetylene bottles, located at the building south entrance, were stored together without proper separation. The Army Corps of Engineers was previously cited for a violation of a similar Occupational Safety and Health Standard 29 CFR 1910.253(b)(4)(i), which was contained in OSHA inspection number 1051499, notice number 1, item number 3 and was affirmed as a final order on 10/20/2015, with respect to a workplace located at Lowell, OR 97452.
Recent events (1)
- — Z (R) $0
1910.242 A
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: Powerhouse #1, North end level 37- (a) The rivet set tool has a mushroomed head, exposing employees to flying metal chips. The Army Corps of Engineers was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.242(a), which was contained in OSHA inspection number 1056022, notice number 3, item number 1 and was affirmed as a final order on 11/05/2015, with respect to a workplace located at Blue River, OR 97413.
Recent events (1)
- — Z (R) $0
1910.29 A04 II
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(a)(4)(ii): All scaffold casters shall be provided with a positive wheel and/or swivel lock to prevent movement. Ladder stands shall have at least two (2) of the four (4) casters and shall be of the swivel type. Fish Screen Assembly Area- (a) The Barrymore Co. rolling ladder stand did not have at least two (2) of the four (4) casters capable of being lock to prevent movement.
Recent events (1)
- — Z (O) $0
1910.37 B05
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Lighting and marking must be adequate and appropriate. Each doorway or passage along an exit access that could be mistaken for an exit must be marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g., closet). Warehouse Annex- (a) The door in the back area of the warehouse was not marked to indicated it was "Not an Exit".
Recent events (1)
- — Z (O) $0
1910.37 B06
- Issued
- Jun 8, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: Warehouse Annex- (a) The exit sign's bulbs were not illuminated at the exit door of the warehouse.
Recent events (1)
- — Z (O) $0
More inspections at Army Corps of Engineers, Bonneville DAM
View Army Corps of Engineers, Bonneville DAM's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in OR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342011566.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.