Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STRATIS INDUSTRIES

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of STRATIS INDUSTRIES in 321 E. 1ST STREET, CENTURIA, WI 54824 (NAICS 321999). OSHA activity number 342017712.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stratis Industries — free Get an email when a new federal OSHA severe-injury report for Stratis Industries is published. One employer, no account, unsubscribe in one click.
Establishment
STRATIS INDUSTRIES
Site address
321 E. 1ST STREET
City
CENTURIA
State
WI
ZIP
54824
Mailing
321 E. 1ST STREET, CENTURIA, WI 54824
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
28
Ownership type
A

7 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 27, 2017
Abate by
Jun 16, 2017
Penalty
Initial $4,183 · Current $2,928 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:      (a) Spray-finishing area; A written respiratory protection program was not developed and implemented before employees were required to wear N95, filtering face-piece respirators.
Recent events (2)
  • — I (S) $2928
  • — Z (S) $4183

1910.134 K03

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 27, 2017
Abate by
Jun 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  (a) Spray-finishing area; Respirator training was not provided before employees were required to wear N95, filtering face-piece respirators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 II

Other-than-serious 1 instance 1 exposed
Issued
Apr 27, 2017
Abate by
May 26, 2017
Penalty
Initial $6,972 · Current $0 Reduced
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not used for lockout and tagout purposes only:    (a) CNC building; A lockout lock was used to remove equipment from service.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6972

1910.147 C05 II D

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 27, 2017
Abate by
May 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):    (a) CNC building; The identity of the employee who locked out an electrical disconnect was not indicated on the lockout tag or device.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 27, 2017
Abate by
May 11, 2017
Penalty
Initial $4,183 · Current $2,928 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:    (a) CNC Building, A flexible cord was run through a wall hole.
Recent events (2)
  • — I (S) $2928
  • — Z (S) $4183

1904.32 B02 II

Other-than-serious 1 instance 28 exposed
Issued
Apr 27, 2017
Abate by
May 8, 2017
Penalty
Initial $1,394 · Current $976 Reduced
29 CFR 1904.32(b)(2)(ii): The employer did not enter the calendar year covered, the company's name, establishment name, establishment address, annual average number of employees covered by the OSHA 300 Log, and the total hours worked by all employees covered by the OSHA 300 Log:      (a) Throughout the facility; The total number of employees and hours worked was not written on the annual summary on injury and illness logs (OSHA form 300-A).
Recent events (2)
  • — I (O) $976
  • — Z (O) $1394

1910.22 D01

Other-than-serious 1 instance 1 exposed
Issued
Apr 27, 2017
Abate by
May 11, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design which were not supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate:  (a) CNC Building; The load rating was not provided for a storage area above the CNC office.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Stratis Industries's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342017712.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.