OSHA Inspection: U.S. DEPARTMENT OF DEFENSE (MARINE CORPS)

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF DEFENSE (MARINE CORPS) in MCMWTC, BLDG. 7056 (HEAVY EQUIPMENT) HC 83, BRIDGEPORT, CA 93517 (NAICS 928110). OSHA activity number 342018116.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Defense (Marine Corps) — free Get an email when a new federal OSHA severe-injury report for U.S. Department of Defense (Marine Corps) is published. One employer, no account, unsubscribe in one click.
Site address
MCMWTC, BLDG. 7056 (HEAVY EQUIPMENT) HC 83
City
BRIDGEPORT
State
CA
ZIP
93517
Mailing
MARINE CORPS MOUNTAIN WARFARE TRAINING CENTER HC83, BRIDGEPORT, CA 93517
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
4
Ownership type
D

5 citations on file for this inspection.

1910.215 A04

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:        Heavy Equipment Shop, Bldg. 7056 - On 10/13/16, a Baldor double wheeled bench grinder did not have the work rests adjusted to 1/8 inch on both the right and left sides.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Jan 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:     Heavy Equipment Shop, Bldg. 7056 - On 10/13/16, a Baldor double wheeled bench grinder did not have the left and right side tongue guards adjusted to within 1/4 inch of the grinding wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:   Heavy Mechanics Shop, Bldg. 7056 - On 10/13/16, an acetylene cylinder was stored in the weld shop with out being restricted from being knocked over.  A separate acetylene storage closet was available outside the shop.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 E02

Other-than-serious 1 instance 4 exposed
Issued
Jan 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(2):  Stair rails did not consist of a top rail, intermediate rail and/or posts, with the vertical height not more than 34 inches (86.36 cm) nor less than 30 inches (76.2 cm) from upper surface of top rail to surface of tread in line with face of riser at forward edge of tread:   Heavy Equipment Shop, Stairway, Bldg. 7056 - On 10/13/16, the stairway leading to the storage mezzanine was not standard in construction; there was no mid-rail and the top rail was less than 34 inches.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.253 B05 II G

Other-than-serious 1 instance 3 exposed
Issued
Jan 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(5)(ii)(G): Cylinder valves shall be closed when work is finished.   Weld Shop, Bldg. 7056 - On 10/13 16, the regulator attached to an Argon cylinder, previously used for welding, indicated that it was still under pressure and therefore the valve was not closed after work was completed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0