BRIDGEPORT, CA —
OSHA Inspection: U.S. DEPARTMENT OF DEFENSE (MARINE CORPS)
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF DEFENSE (MARINE CORPS) in MCMWTC HC 83, BRIDGEPORT, CA 93517 (NAICS 928110). OSHA activity number 342019064.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. DEPARTMENT OF DEFENSE (MARINE CORPS)
- Site address
- MCMWTC HC 83
- City
- BRIDGEPORT
- State
- CA
- ZIP
- 93517
- Mailing
- MARINE CORPS MOUNTAIN WARFARE TRAINING CENTER HC83, BRIDGEPORT, CA 93517
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 4
- Ownership type
- D
Citations
1 citation on file for this inspection.
1910.23 C01
- Issued
- Jan 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toe board wherever, beneath the open sides, Supply Warehouse, Storage Mezzanine, Bldg. 7047 - On 10/13/16, the standard railing of the storage mezzanine did not completely protect employees from fall hazards of over 10 feet; there were three sections of railing that had gaps ranging from 8-12 inches and did not provide adequate fall protection. Additionally, toe boards were either missing from the gapped sections or pushed out in excess of 1/4 inch.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at U.S. Department of Defense (Marine Corps)
View U.S. Department of Defense (Marine Corps)'s full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342019064.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.