Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARCHITECTURAL SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARCHITECTURAL SYSTEMS, INC. in 170 NORTH SUNBURY ROAD, WESTERVILLE, OH 43081 (NAICS 238160). OSHA activity number 342038692.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Architectural Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Architectural Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
170 NORTH SUNBURY ROAD
City
WESTERVILLE
State
OH
ZIP
43081
Mailing
8633 MEMORIAL DRIVE, PLAIN CITY, OH 43064
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
80
Ownership type
A

1 citation on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 12, 2017
Abate by
Apr 24, 2017
Penalty
Initial $5,387 · Current $3,771 Reduced
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted:   a. On or about January 18, 2017, at the job site, employees performing roofing activities/installing rubber membrane on the roof were not protected from falling by a guardrail system, safety net system, personal fall arrest system, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system, thereby exposing the employees to a fall hazard of approximately 15 feet.
Recent events (2)
  • — I (S) $3770.9
  • — Z (S) $5387

View Architectural Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342038692.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.