OSHA Inspection: SOUTHSIDE HOSPITAL

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SOUTHSIDE HOSPITAL in 301 E. MAIN ST., BAY SHORE, NY 11706 (NAICS 622110). OSHA activity number 342054434.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southside Hospital — free Get an email when a new federal OSHA severe-injury report for Southside Hospital is published. One employer, no account, unsubscribe in one click.
Establishment
SOUTHSIDE HOSPITAL
Site address
301 E. MAIN ST.
City
BAY SHORE
State
NY
ZIP
11706
Mailing
1983 MARCUS AVE. SUITE 138, LAKE SUCCESS, NY 11020
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
2500
Ownership type
A

4 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 2 instances 4 exposed
Issued
Jul 17, 2017
Abate by
Sep 15, 2017
Penalty
Initial $9,054 · Current $6,337 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling:    a) Worksite, Gulden Machine Room, Southside Hospital: A walking working surface greater than four feet above the ground was unguarded; on or about 1/25/17.     Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $6337
  • — Z (S) $9054

1910.147 D02

Serious Gravity 10 3 instances 4 exposed
Issued
Jul 17, 2017
Abate by
Sep 15, 2017
Penalty
Initial $12,675 · Current $8,873 Reduced
29 CFR 1910.147(d)(2): Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.      a) Worksite, Gulden Wing, Southside Hospital: Employees who perform servicing and maintenance work on boilers were not provided with or utilizing energy control procedures or an alternate means of protection; on or about 1/25/17.    b) Worksite, Gulden Wing, Southside Hospital: Employees who perform servicing and maintenance work on air handling units/HVAC were not provided with or utilizing energy control procedures or an alternate means of protection; on or about 1/25/17.       Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $8873
  • — Z (S) $12675

1910.147 C06 I

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jul 17, 2017
Abate by
Aug 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Worksite: Energy control procedures for equipment such as, but not limited to, boilers, air handling units, and condensate lines, were developed but were not being utilized. An adequate periodic inspection was not conducted to identify and correct inadequacies or deviations from the procedures; on or about 1/17/17.  Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jul 17, 2017
Abate by
Aug 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  a) Worksite: Employees were not provided with adequate training on the energy control program regarding the utilization of specific written procedures during servicing and maintenance work; on or about 1/17/17.    Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Southside Hospital's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342054434.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.