DUNMORE, PA —
OSHA Inspection: EASTERN ROOFING SYSTEMS, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of EASTERN ROOFING SYSTEMS, INC. in 200 TIGUE STREET, DUNMORE, PA 18512 (NAICS 238160). OSHA activity number 342055274.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EASTERN ROOFING SYSTEMS, INC.
- Site address
- 200 TIGUE STREET
- City
- DUNMORE
- State
- PA
- ZIP
- 18512
- Mailing
- 1 KEYSTONE PLACE, JESSUP, PA 18434
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Mar 31, 2017
- Abate by
- Apr 12, 2017
- Penalty
- Initial $8,963 · Current $7,750 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Dunmore, PA: Employees were not protected from falls ranging from 16 to 27 feet while sweeping water from a flat roof in preparation for construction activities, on or about January 26, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $7750
- — Z (S) $8963
1926.1053 B01
- Issued
- Mar 31, 2017
- Abate by
- Apr 12, 2017
- Penalty
- Initial $7,171 · Current $4,350 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders used for access to an upper landing surface did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: a) Dunmore, PA: Employees were using a 12-foot step ladder to access a roof and the ladder did not extend at least 3 feet above the landing surface or otherwise secured exposing workers to a fall, on or about January 26, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $4350
- — Z (S) $7171
1926.1053 B04
- Issued
- Mar 31, 2017
- Abate by
- Apr 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders used for purposes other than which they were designed: a) Dunmore, PA: Employees were using a folded 12-foot step ladder to traverse from one roof level to another, exposing employees to the hazard of falling, on or about January 26, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Eastern Roofing Systems, INC.
View Eastern Roofing Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342055274.