Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPARTMENT OF THE INTERIOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF THE INTERIOR in 1214 MIDDLE STREET, SULLIVANS ISLAND, SC 29482 (NAICS 712120). OSHA activity number 342055324.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of the Interior — free Get an email when a new federal OSHA severe-injury report for U.S. Department of the Interior is published. One employer, no account, unsubscribe in one click.
Site address
1214 MIDDLE STREET
City
SULLIVANS ISLAND
State
SC
ZIP
29482
Mailing
1214 MIDDLE STREET, SULLIVANS ISLAND, SC 29482
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712120
Employees
10
Ownership type
D

5 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 14, 2017
Abate by
Mar 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(1)(i): (1) Unprotected sides and edges.  (i) Except as provided elsewhere in this section, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems; safety net systems; or personal fall arrest systems.   a) South end of the Maintenance Office Building grounds: When employees are entering/exiting the door to the office building and/or using the concrete walkway to the parking lot they are exposed to falling 14 feet 9 inches to the ground below.   ABATEMENT DOCUMENTATION IS REQUIRED.
Recent events (1)
  • — Z (S) $0

1910.178 P01

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 14, 2017
Abate by
Feb 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  a) Lifesaving Station Worksite: A Komatsu Forklift USNPS 59616 used at the site to load and unload supplies was equipped with a nonfunctioning horn.   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  a) West wall of the Maintenance Office Break Room: An energized 120 volt relocatable power tap was found to be screwed into a wall requiring the use of hand tools to remove it. This is a violation of it's listing due to it no longer being relocatable.  b) North wall of the Lifesaving Station Maintenance Shop: A Titan tankless water heater designed and listed to have its electrical power cord to be plugged directly into a wall mounted receptacle outlet was instead plugged into a multi tap.
Recent events (1)
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:    a)    Southwest corner of the Lifesaving Station Maintenance Shop: The electrical cord to the Makita 12 inch metal cutting saw, model number LC1230; was found to have a 1/2 section of the outer insulation exposed near the plug-end and a couple inches to the plug-end was another cut which went around the entire circumference of the cord exposing the wires underneath to contact with the elements and employees.
Recent events (1)
  • — Z (S) $0

1960.59 A

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 14, 2017
Abate by
Feb 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1960.59(a): The Agency did not provide appropriate safety and health training for employees:   a) Southwest corner of the Lifesaving Station Maintenance Shop:  The employer did not ensure employees were trained to recognize that an unstable, wobbly  three legged worktable used to support a metal cutting saw during cutting operations was a safety hazard and can not be used.   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
  • — Z (S) $0

View U.S. Department of the Interior's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342055324.