Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STEVENS COMPANY, INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STEVENS COMPANY, INCORPORATED in 1085 WATERBURY ROAD, SUITE 1, THOMASTON, CT 06787 (NAICS 332116). OSHA activity number 342059839.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stevens Company, Incorporated — free Get an email when a new federal OSHA severe-injury report for Stevens Company, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
1085 WATERBURY ROAD, SUITE 1
City
THOMASTON
State
CT
ZIP
06787
Mailing
1085 WATERBURY ROAD, SUITE 1, THOMASTON, CT 06787
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
35
Ownership type
A

11 citations on file for this inspection.

1910.212 A04

Serious Gravity 5 1 instance 4 exposed
Issued
May 9, 2017
Abate by
Jun 26, 2017
Penalty
Initial $3,803 · Current $2,662 Reduced
29 CFR 1910.212(a)(4): Revolving drum(s), barrel(s), or container(s) were not guarded by enclosure(s) which were interlocked with the drive mechanism so that the barrel(s), drum(s), or container(s) could not revolve unless the enclosure(s) were in place:     Press Department:  On, or about, March 20, 2017, the revolving drum tumbler was not provided with an interlocked enclosure.
Recent events (2)
  • — I (S) $2662.1
  • — Z (S) $3803

1910.215 A02

Serious Gravity 5 2 instances 2 exposed
Issued
May 9, 2017
Abate by
Jun 26, 2017
Penalty
Initial $3,803 · Current $2,662 Reduced
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:    Grinding Room:  On, or about, March 20, 2017, the hood guards provided on the following surface grinders did not enclose the spindle, nut and flange projections:   A.   Taft-Pierre. B.   Boyar-Shultz.
Recent events (2)
  • — I (S) $2662.1
  • — Z (S) $3803

1910.215 B05

Serious Gravity 5 2 instances 2 exposed
Issued
May 9, 2017
Abate by
Jun 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(5): The angular exposure of grinding wheel periphery and sides for safety guards used on surface grinding machine(s) employing the wheel periphery exceeded 150 degrees:  Grinding Room:  On, or about, March 20, 2017, the hood guards provided on the following surface grinders did not limit the angular exposure of the abrasive wheel to 150 degrees or less:    A.   Taft-Pierre. B.   Norton.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 B07 VIII

Serious Gravity 5 2 instances 2 exposed
Issued
May 9, 2017
Abate by
Jun 26, 2017
Penalty
Initial $3,803 · Current $2,662 Reduced
29 CFR 1910.217(b)(7)(viii): Mechanical power press(es) using part revolution clutches, with clutch/brake control systems which contained both single and continuous functions, were not designed so that in order to initiate a continuous run, a prior action or decision by the operator in addition to the selection of Continuous on the stroking selector, before actuation of the operating means will result in continuous stroking:       Press Room:  The following partial revolution mechanical power presses were not provided with operational arming controls to start the press continuous stroking mode:    A.  On, or about, March 20, 2017, Press # 74, Minster. B.  On, or about, April 24, 2017, Press #56, Perkins.
Recent events (2)
  • — I (S) $2662.1
  • — Z (S) $3803

1910.217 E01 I A

Serious Gravity 5 1 instance 4 exposed
Issued
May 9, 2017
Abate by
Jun 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.217(e)(1)(i)(A): Conduct periodic and regular inspections of each power press to ensure that all of its parts, auxiliary equipment, and safeguards, including the clutch/brake mechanism, anti-repeat feature, and single-stroke mechanism, are in a safe operating condition and adjustment:  Company:  On, or about, April 24, 2017, the company had not developed and implemented a program of periodic, documented inspections of mechanical power presses that was more comprehensive in nature than the weekly inspections that were being conducted at the time of the inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 B07 XIII

Serious Gravity 1 3 instances 2 exposed
Issued
May 9, 2017
Penalty
Initial $2,852 · Current $1,996 Reduced
29 CFR 1910.217(b)(7)(xiii): The clutch/brake control of mechanical power press(es) with part revolution clutches did not automatically deactivate in event of failure of the power or pressure supply for the clutch engaging means and did not require restoration of the normal supply and the use of the tripping mechanism:   Press Room:  On, or about, March 20, 2017, the following Bliss partial revolution mechanical power presses were not provided with an air pressure switch on the clutch air line:  A.  Press #31.    B.  Press #39. C.  Press #34.
Recent events (2)
  • — I (S) $1996.4
  • — Z (S) $2852

1910.217 B07 XIV

Serious Gravity 1 3 instances 2 exposed
Issued
May 9, 2017
Abate by
Jun 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(7)(xiv): The clutch/brake control did not automatically deactivate in event of failure of the counterbalance(s) air supply. Reactivation of the clutch shall require restoration of normal air supply and use of the tripping mechanism(s):  Press Room:  On, or about, March 20, 2017, the following Bliss partial revolution mechanical power presses were not provided with an air pressure switch on the air counterbalance system:  A.  Press #31. B.  Press #39. C.  Press #34.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 2 instances 2 exposed
Issued
May 9, 2017
Penalty
Initial $3,232 · Current $2,262 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    Press Room:  On, or about, March 20, 2017, Star Chopper scrap choppers located at the following presses were not provided with a guard over the rotating shaft and coupling:  A.   Press #32. B.   Press #33.
Recent events (2)
  • — I (S) $2262.4
  • — Z (S) $3232

1910.147 C06 I

Other-than-serious 1 instance 5 exposed
Issued
May 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   Company:  On, or about, January 27, 2017, the employer had not conducted an annual review of the energy control procedures included in the lockout program since 2015 .
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.213 B03

Other-than-serious 1 instance 1 exposed
Issued
May 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:    Maintenance Shop:  On, or about, March 20, 2017, the Sears Craftsman table saw was not provided with a drop-out starter or the equivalent to prevent restarting of the machine following a loss of power.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.217 B12

Other-than-serious 3 instances 2 exposed
Issued
May 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(12): All pressure vessels used in conjunction with power presses did not conform to the American Society of Mechanical Engineers Code for Pressure Vessels, 1968 Edition:  Ref. UG-125  Fastener Department:  On, or about, March 20, 2017, the following partial revolution mechanical power presses were not provided with a pressure relief device on the air tank(s):  A.   V&O, brass tag 5078. B.   V&O, brass tag 5079. C.   V&O, brass tag 5075.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Stevens Company, Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342059839.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.