WILLIAMSVILLE, NY —
OSHA Inspection: S.A.B. SPECIALTIES, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of S.A.B. SPECIALTIES, LLC in 408 MILL STREET, WILLIAMSVILLE, NY 14221 (NAICS 238130). OSHA activity number 342060050.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S.A.B. SPECIALTIES, LLC
- Site address
- 408 MILL STREET
- City
- WILLIAMSVILLE
- State
- NY
- ZIP
- 14221
- Mailing
- 5260 ROGERS ROAD, HAMBURG, NY 14075
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.502 B03
- Issued
- Jul 5, 2017
- Penalty
- Initial $8,873 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: a) On or about 1/11/17 on the exterior deck/balcony of unit 313 and other second and third story exterior decks/balconies of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY: Temporary wood guardrails were installed along the two open sides of the decks/balconies to protect workers from falls of approx. 11 ft. from second story exterior decks /balconies to approx. 21 ft. 6 in. from third story exterior decks/balconies. On the unit 313 deck/balcony, the guardrail system consisted of one vertical 6 x 6 inch wood structural post in the northeast corner, one vertical wood 2x 4 nailed into the wall of the mechanical room at the northwest corner of the deck/balcony, one vertical wood 2x 4 nailed into the wall of the building at the southeast corner of the deck/balcony. Horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails were nailed into the vertical members to form the guardrail system . The horizontal spans of the toprails and midrails on the outside end of the decks /balconies were approx. 11 feet 4 inches. The horizontal spans of the toprails and midrails on the east side of the unit 313 deck/balcony were approx. 9 feet 3 inches. The horizontal spans on the toprails and midrails of unit 313 deck/balcony and all other decks/balconies were greater than the 8 foot span between vertical posts recommended for wooden guardrails in Appendix B of Subpart M of this standard. Additionally, all the top and mid rails were nailed on the outside of the vertical posts of the unit 313 deck/balcony and most of the other decks/balconies. Some decks/balconies had top and/or midrails that had failed ,were missing, or had been spliced . Most decks /balconies had identical dimensions. An employee fell 21 ft. 6 in. when both the top and midrail failed on the north end of the unit 313 deck/balcony. NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (3)
- — J (O) $2000
- — C (S) $8873
- — Z (S) $8873
1926.502 B05
- Issued
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(5): Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members were not capable of withstanding, without failure, a force of at least 150 pounds (666 N) applied in any downward or outward direction at any point along the midrail or other member: a) On or about 1/11/17 on the exterior deck/balcony of unit 313 and other second and third story exterior decks/balconies of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY: Temporary wood guardrails were installed along the two open sides of the decks/balconies to protect workers from falls of approx. 11 ft. from second story exterior decks /balconies to approx. 21 ft. 6 in. from third story exterior decks/balconies. On the unit 313 deck/balcony, the guardrail system consisted of one vertical 6 x 6 inch wood structural post in the northeast corner, one vertical wood 2x 4 nailed into the wall of the mechanical room at the northwest corner of the deck/balcony, one vertical wood 2x 4 nailed into the wall of the building at the southeast corner of the deck/balcony. Horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails were nailed into the vertical members to form the guardrail system . The horizontal spans of the toprails and midrails on the outside end of the decks /balconies were approx. 11 feet 4 inches. The horizontal spans of the toprails and midrails on the east side of the unit 313 deck/balcony were approx. 9 feet 3 inches. The horizontal spans on the toprails and midrails of unit 313 deck/balcony and all other decks/balconies were greater than the 8 foot span between vertical posts recommended for wooden guardrails in Appendix B of Subpart M of this standard. Additionally, all the top and mid rails were nailed on the outside of the vertical posts of the unit 313 deck/balcony and most of the other decks/balconies. Some decks/balconies had top and/or midrails that had failed ,were missing, or had been spliced . Most decks /balconies had identical dimensions. An employee fell 21 ft. 6 in. when both the top and midrail failed on the north end of the unit 313 deck/balcony. NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
More inspections at S.A.B. Specialties, LLC