AUSTIN, TX —
OSHA Inspection: AECOM COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AECOM COMPANY in 101 RED RIVER ST, AUSTIN, TX 78701 (NAICS 236220). OSHA activity number 342069697.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AECOM COMPANY
- Site address
- 101 RED RIVER ST
- City
- AUSTIN
- State
- TX
- ZIP
- 78701
- Mailing
- 2450 S. TIBBS AVE, INDIANAPOLIS, IN 46241
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 5000
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.405 B01
- Issued
- Apr 24, 2017
- Abate by
- May 1, 2017
- Penalty
- Initial $5,432 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes and fittings were not effectively closed. On or about January 27, 2017, and at times prior thereto, the electrical box on the Hercules Elevator had a missing knockout, exposing employees to the hazard of electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $5432
1926.405 G02 IV
- Issued
- Apr 24, 2017
- Abate by
- May 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: On or about January 27, 2017, and at times prior thereto, two power cords on the Hercules Elevator had the outer sheathing pulled back with exposed inner wires, exposing employees to the hazard of electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.552 B03
- Issued
- Apr 24, 2017
- Abate by
- May 1, 2017
- Penalty
- Initial $9,054 · Current $7,243 Reduced
General-duty citation text
29 CFR 1926.552(b)(3): Overhead protection covering of 2-inch planking, 4-Mar inch plywood, or other solid material of equivalent strength was not provided on the top of every material hoist cage or platform: On or about January 27, 2017, a cable guide bracket from the tower of the Hercules Elevator fell approximately 25 floors and almost struck an employee standing on the platform that was not completely covered by overhead protection, exposing employees to the hazard of being struck by falling material or parts of the elevator/hoist.
Recent events (2)
- — I (O) $7243
- — Z (S) $9054
More inspections at Aecom Company
View Aecom Company's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342069697.