FREMONT, NE —
OSHA Inspection: GAVILON GRAIN, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GAVILON GRAIN, LLC in 1700 FRONT ST, FREMONT, NE 68025 (NAICS 424510). OSHA activity number 342071388.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GAVILON GRAIN, LLC
- Site address
- 1700 FRONT ST
- City
- FREMONT
- State
- NE
- ZIP
- 68025
- Mailing
- 1700 FRONT ST, FREMONT, NE 68025
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 10
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.307 C02 I
- Issued
- Jul 18, 2017
- Abate by
- Aug 18, 2018
- Penalty
- Initial $0 · Current $5,250
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the class of location: The employer is failing to protect employees from explosion hazards associated with using unapproved equipment in a combustible dust environment. The most recent occurrence of this was evident during the inspection of the facility located at 1700 E. Front St. Fremont, NE, where the employer has installed an unapproved Pelonis Convection Oil Filled Radiator Heater as means of providing heat in the load out control shed where the presence of combustible grain dust is evident during every delivery.
Recent events (3)
- — F (O) $5250
- — C (S) $0
- — Z (S) $0
5(a)(1)
- Issued
- Jul 18, 2017
- Abate by
- Aug 2, 2017
- Penalty
- Initial $9,959 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm including severe burns, to employees in that employees were exposed to dust explosion, deflagration, or other fire hazards from an electric heater: During the inspection on February 1, 2017 of the facility located at 1700 E. Front St. Fremont, NE, it was observed that the employer was failing to protect employees from fire and explosion hazards. This was the result of the employer installing a Pelonis Convection Oil Filled Radiator Heater as means of providing comfort heat in the load out control shed where the presence of combustible grain dust. Among other methods, a feasible abatement method to correct this hazard, such as, but not limited to, the National Fire Prevention Association (NFPA) standard 61 2017 Prevention of Fires and Dusts Explosions in Agricultural and Food Processing Facilities Section 8.3.10.2 Comfort Heating, states that: i. Heating with electric power requires a heater that meets the requirements of suitability for a Class 2 Division II as required by NFPA 70. ii. Heating must be steam or hot water from a boiler in an approved location, or from electric hot water radiators of a type approved for Class II locations. Steam pipes exposed to dust accumulations shall be protected by suitable insulation having continuous nonporous covering or skin of adequate thickness to keep the surface temperature below 160 degrees Fahrenheit.
Recent events (3)
- — F (S) $0
- — C (S) $9959
- — Z (S) $9959
1910.132 E
- Issued
- Jul 18, 2017
- Abate by
- Aug 18, 2018
- Penalty
- Initial $9,959 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.132(e): Defective or damaged personal protective equipment shall not be used. The employer is failing to protect employees from fall hazards associated with using defective or damaged fall arrest system. The most recent occurrence of this was evident during the inspection of the facility located at 1700 E. Front St. Fremont, NE, where the employer has employees utilizing fall protection in which the retractable was exposed to conditions from being extended for long periods of time and experienced shock loading as the result of an employee falling from a railcar.
Recent events (3)
- — F (S) $7000
- — C (S) $9959
- — Z (S) $9959
1910.132 F01
- Issued
- Jul 18, 2017
- Abate by
- Aug 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment: The employer is failing to provide employees with training associated with the wear, use, inspection of, limitations and maintenance of fall protection equipment. The most recent occurrence of this was evident during the inspection of the facility located at 1700 E. Front St. Fremont, NE, where the employer has inadequately trained employees using fall arrest harnesses, lanyards and self-retracting lifelines as means of protection from falling as they work on top of railcars over 13 feet above the ground, opening and closing the lids.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.145 C03
- Issued
- Jul 18, 2017
- Abate by
- Aug 18, 2018
- Penalty
- Initial $7,967 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s): The employer is failing to protect employees from overhead struck-by hazards associated with falling debris. The most recent occurrence of this was evident during the inspection of the facility located at 1700 E. Front St. Fremont, NE, where the employer has employees performing grain handling tasks in and around the facility to include working below bin number 303 which has an aging condition that causes chucks of concrete to fall randomly without control approximately 140 feet to the ground below.
Recent events (3)
- — F (S) $6000
- — C (S) $7967
- — Z (S) $7967
1910.333 B02 IV B
- Issued
- Jul 18, 2017
- Abate by
- Aug 18, 2018
- Penalty
- Initial $0 · Current $9,000
General-duty citation text
29 CFR 1910.333(b)(2)(iv)(B): Before circuits or equipment was worked as deenergized, a qualified person did not use test equipment to test the circuit elements and electrical parts of equipment to which employees would be exposed and did not verify that the circuit elements and equipment parts were deenergized: The employer is failing to protect employees from electrical hazards associated with working on or near live electrical without having a qualified person test the wiring. The most recent occurrence of this was evident during the inspection of the facility located at 1700 E. Front St. Fremont, NE, where the employer has employees assisting in the removal of electrical conduit and wiring without a qualified person testing the wiring to ensure it is de-energized.
Recent events (3)
- — F (S) $9000
- — C (S) $0
- — Z (S) $0
1910.332 B01
- Issued
- Jul 18, 2017
- Abate by
- Aug 2, 2017
- Penalty
- Initial $12,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: The employer is failing to provide electrical training to employees associated with safety-related work practices as they pertain to their respective job assignment. The most recent occurrence of this was evident during the inspection of the facility located at 1700 E. Front St. Fremont, NE, where the employer has inadequately trained employees using a reciprocating saw in the demolition and removal of live electrical conduit and wiring.
Recent events (3)
- — F (S) $0
- — C (S) $12675
- — Z (S) $12675
1910.334 A03 I
- Issued
- Jul 18, 2017
- Abate by
- Aug 18, 2018
- Penalty
- Initial $9,959 · Current $5,250 Reduced
General-duty citation text
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor. The employer is failing to protect employees from electrical and explosion hazards associated with using ungrounded equipment in a combustible dust environment. The most recent occurrence of this was evident during the inspection of the facility located at 1700 E. Front St. Fremont, NE, where the employer has installed a Pelonis Convection Oil Filled Radiator Heater as means of providing heat in the load out control shed where the presence of combustible grain dust is evident during every delivery.
Recent events (3)
- — F (O) $5250
- — C (S) $9959
- — Z (S) $9959
More inspections at Gavilon Grain, LLC
View Gavilon Grain, LLC's full OSHA safety record →
More inspections in this industry (NAICS 424510)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342071388.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.