OSHA Inspection: HERCULES CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HERCULES CONSTRUCTION LLC in 1217 TRINIDAD AVENUE, NE, WASHINGTON, DC 20002 (NAICS 238160). OSHA activity number 342076189.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hercules Construction LLC — free Get an email when a new federal OSHA severe-injury report for Hercules Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
1217 TRINIDAD AVENUE, NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
13003 THYME COURT, GERMANTOWN, MD 20874
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 28, 2017
Abate by
Mar 6, 2017
Penalty
Initial $3,803 · Current $1,800 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     (a)  Front Porch Rooftop - On or about February 1, 2017, workers were observed replacing a rooftop while working at the edge without using fall protection and were exposed to a 12 foot 8 inch fall hazard.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3803

View Hercules Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342076189.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.