Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FEDERAL BUREAU OF PRISONS F.C.I. MILAN

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FEDERAL BUREAU OF PRISONS F.C.I. MILAN in 4004 ARKONA ROAD, MILAN, MI 48160 (NAICS 922140). OSHA activity number 342091519.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Federal Bureau of Prisons F.C.I. Milan — free Get an email when a new federal OSHA severe-injury report for Federal Bureau of Prisons F.C.I. Milan is published. One employer, no account, unsubscribe in one click.
Site address
4004 ARKONA ROAD
City
MILAN
State
MI
ZIP
48160
Mailing
P.O. BOX 9999, MILAN, MI 48160
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922140
Employees
200
Ownership type
D

3 citations on file for this inspection.

1910.29 F04

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.29(f)(4) as required by 1960.8(b): Openings in stair rails.  No opening in a stair rail system exceeds 19 inches (48 cm) at its least dimension:  On or about February 10, 2017, in the UNICOR facility press area, a stairway with 13 risers leading up to the press foreman's office was not provided with a stair rail in that the railing did not have a midrail leaving large openings in the stair rail, there by exposing employees to a fall hazard.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1) as required by 1960.8(b): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a. On or about February 9, 2017, in the UNICOR facility tool and die area, Fortune 1640 Metal Lathe, was not equipped with a guard at the rotating chuck, exposing employees to a struck by, caught in and/or caught on hazard.   b. On or about February 9, 2017, in the UNICOR facility tool and die area, Fortune 1640 Metal Lathe, was not equipped with a guard at the hole through spindle, exposing employees to a struck by, caught in and/or caught on hazard.
Recent events (1)
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b) as required by 1960.8(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:   On or about February 10, 2017, in the UNICOR facility tool and die area, the employer did not reduced the air pressure to 30 p.s.i. on air nozzles used for cleaning parts. The air pressure was set at approximately 100 p.s.i., there by exposing employees to a struck by hazard.
Recent events (1)
  • — Z (S) $0

View Federal Bureau of Prisons F.C.I. Milan's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342091519.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.