PHILADELPHIA, PA —
OSHA Inspection: DN CONSTRUCTION, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DN CONSTRUCTION, LLC in 1333 BAINBRIDGE ST, PHILADELPHIA, PA 19147 (NAICS 236116). OSHA activity number 342092137.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DN CONSTRUCTION, LLC
- Site address
- 1333 BAINBRIDGE ST
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19147
- Mailing
- 9304 KEYSTONE ST, PHILADELPHIA, PA 19114
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 4
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.404 B01 II
- Issued
- Feb 24, 2017
- Abate by
- Mar 6, 2017
- Penalty
- Initial $2,988 · Current $1,942 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection a) 1333 Bainbridge St, Philadelphia, PA: On or about 01/12/2017, the employer did not provide functioning ground fault circuit interruption on temporary wiring for employees using an angle grinder, thus exposing the employees to electric shock.
Recent events (2)
- — I (S) $1942.2
- — Z (S) $2988
1926.405 A02 II C
- Issued
- Feb 24, 2017
- Abate by
- Mar 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(C): All receptacles used on temporary wiring with a separate equipment grounding conductor were not electrically connected to the grounding conductor: a) 1333 Bainbridge St, Philadelphia, PA: On or about 01/12/2017, the employer did not provide extension cords with electrically connected ground conductor for employees using an angle grinder, thus exposing the employees to electric shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G02 IV
- Issued
- Feb 24, 2017
- Abate by
- Mar 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) 1333 Bainbridge St, Philadelphia, PA: On or about 01/12/2017, the employer did not provide strain relief on extension cords for employees using an angle grinder, thus exposing the employees to electric shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G02 III
- Issued
- Feb 24, 2017
- Abate by
- Mar 6, 2017
- Penalty
- Initial $2,988 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used: a) 1333 Bainbridge St, Philadelphia, PA: On or about 01/12/2017, the employer did not provide extension cords which were of a continuous length or repaired in accordance with their listing for employees using an angle grinder, thus exposing the employees to electric shock.
Recent events (2)
- — I (S) $0
- — Z (S) $2988
1926.451 B01
- Issued
- Feb 24, 2017
- Abate by
- Mar 6, 2017
- Penalty
- Initial $4,183 · Current $2,719 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) (a) 1333 Bainbridge St, Philadelphia, PA: On or about 01/12/2017, employees were working from a fabricated-frame scaffold, approx. 16 feet from the ground level, that was not fully planked, thus exposing the employees to fall hazards.
Recent events (2)
- — I (S) $2718.95
- — Z (S) $4183
1926.451 C02
- Issued
- Feb 24, 2017
- Abate by
- Mar 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: (a) 1333 Bainbridge St, Philadelphia, PA: On or about 01/12/2017, employees were working from a fabricated-frame scaffold, approx. 16 feet from the ground level, that was not provided with baseplates, thus exposing the employees to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Feb 24, 2017
- Abate by
- Mar 6, 2017
- Penalty
- Initial $4,183 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. (a) 1333 Bainbridge St, Philadelphia, PA: On or about 01/12/2017, employees working from a fabricated-frame scaffold, approx. 16 feet from the ground level, were not provided with access to the working platform, thus exposing the employees to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $4183
1926.451 G01
- Issued
- Feb 24, 2017
- Abate by
- Mar 6, 2017
- Penalty
- Initial $4,183 · Current $2,719 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) 1333 Bainbridge St, Philadelphia, PA: On or about 01/12/2017, employees working from a fabricated-frame scaffold, approx. 16 feet from the ground level, were not provided with fall protection, thus exposing the employees to fall hazards.
Recent events (2)
- — I (S) $2718.95
- — Z (S) $4183
More inspections at DN Construction, LLC
View DN Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in PA
Source