Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAYNOR CONSTRUCTION, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MAYNOR CONSTRUCTION, LLC. in 8312 I-35, AUSTIN, TX 78753 (NAICS 238140). OSHA activity number 342099264.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maynor Construction, LLC. — free Get an email when a new federal OSHA severe-injury report for Maynor Construction, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
8312 I-35
City
AUSTIN
State
TX
ZIP
78753
Mailing
10404 DOC HOLLIDAY TRL., AUSTIN, TX 78753
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
10
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 27, 2017
Abate by
May 4, 2017
Penalty
Initial $1,630 · Current $1,630
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:  On or about February 10, 2017, and at times prior thereto, multiple employees were not protected by hard hats while performing renovation work on the apartment complex, exposing the employees to the hazards of being struck by falling debris or construction materials.
Recent events (1)
  • — Z (S) $1630

1926.102 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 27, 2017
Abate by
May 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.  On or about February 10, 2017, and at times prior thereto, three employees were not protected by eye or face protection while using pneumatic hammers on the construction site, exposing the employees to the hazard of being struck by flying debris.
Recent events (1)
  • — Z (S) $0

1926.451 A06

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 27, 2017
Abate by
May 4, 2017
Penalty
Initial $2,716 · Current $2,716
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person and were not constructed and loaded in accordance with that design:  On or about February 10, 2017, and at times prior thereto, employees were working on the two tier scaffolding erected next to the apartment complex under renovation, the scaffolding system had multiple deficiencies, such as: not being fully planked, missing ladders and no guard rails on the second tier.
Recent events (1)
  • — Z (S) $2716

1926.451 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 27, 2017
Abate by
May 4, 2017
Penalty
Initial $2,716 · Current $2,716
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):  On or about February 10, 2017, and at times prior thereto, two employees were conducting renovation work on top of the second tier of the two tier scaffolding system and it was not fully planked between the uprights, exposing the employees to a fall hazard of approximately 14 feet.
Recent events (1)
  • — Z (S) $2716

1926.451 C02

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 27, 2017
Abate by
May 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates, mud sills or other adequate firm foundations:  On or about February 10, 2017, and at times prior thereto, the scaffolding erected next to the apartment under renovation was missing base plates and mud sills on several legs of the upright supports, exposing employees to the hazard of a scaffold collapse.
Recent events (1)
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 27, 2017
Abate by
May 4, 2017
Penalty
Initial $2,716 · Current $2,716
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to the lower level:   On or about February 10, 2017, and at times prior thereto, two employees were conducting renovation work on top of the second tier of the two tier scaffolding system and were not protected by a guardrail system, exposing the employees to a fall hazard of approximately 14 feet.
Recent events (1)
  • — Z (S) $2716

View Maynor Construction, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342099264.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.