MAMARONECK, NY —
OSHA Inspection: ARCTIC GLACIER U.S.A., INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ARCTIC GLACIER U.S.A., INC. in 500 FENIMORE ROAD, MAMARONECK, NY 10543 (NAICS 312113). OSHA activity number 342120706.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCTIC GLACIER U.S.A., INC.
- Site address
- 500 FENIMORE ROAD
- City
- MAMARONECK
- State
- NY
- ZIP
- 10543
- Mailing
- 500 FENIMORE ROAD, MAMARONECK, NY 10543
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 312113
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.37 A04
- Issued
- May 8, 2017
- Abate by
- Jun 2, 2017
- Penalty
- Initial $9,959 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: Location: Engine Room, 500 Fenimore Road, Mamaroneck, NY 10543 On or about 11/14/16 a) A dual head emergency lighting fixture did not operate when the test button was activated. The battery back up used to power the exit lighting in the event of a power failure was not functioning. b) A combination dual head emergency lighting, illuminated exit sign fixture did not operate when the test button was activated. The battery back up used to power the exit lighting in the event of a power failure was not functioning.
Recent events (3)
- — R (S) $0
- — C (S) $9959
- — Z (S) $9959
1910.212 B
- Issued
- May 8, 2017
- Penalty
- Initial $5,975 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: Location: Maintenance Shop, 500 Fenimore Road, Mamaroneck, NY 10543 On or about 11/14/16 a) The Craftsman pedestal drill press was not anchored to the floor.
Recent events (3)
- — J (S) $0
- — C (S) $5975
- — Z (S) $5975
1910.253 B04 III
- Issued
- May 8, 2017
- Abate by
- Jun 2, 2017
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: Location: Maintenance shop, 500 Fenimore Road, Mamaroneck, NY 10543 On or about 11/14/16 a) Oxygen, Acetylene and Propane cylinders were stored immediately next to each other.
Recent events (3)
- — J (S) $9959
- — C (S) $9959
- — Z (S) $9959
1910.303 B01
- Issued
- May 8, 2017
- Abate by
- Jun 2, 2017
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1): Location: a) Wall behind Mycom Compressor RC-6, Ammonia Engine Room, 500 Fenimore Road, Mamaroneck, NY 10543 b,c,d,e) Sump pump contactors 1&2, Ammonia Engine Room, 500 Fenimore Road, Mamaroneck, NY 10543 On or about 11/14/16 a) A section of the protective front cover on the 208/120 volt wireway was missing. b) The face plate of a 120-volt wet location outlet box was wrapped and held in place with electrical tape. c) Conductors entering a 120-volt male plug did not have strain relief. d) Conductors entering a 120-volt female plug did not have adequate strain relief. e) Conductors in a wet location were connected using a "wire nut" wrapped in tape that did not create a seal.
Recent events (3)
- — J (O) $9959
- — C (S) $9959
- — Z (S) $9959
1910.305 B01 II
- Issued
- May 8, 2017
- Penalty
- Initial $5,975 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Location: Maintenance Shop, 500 Fenimore Road, Mamaroneck, NY 10543 On or about: 11/14/16 a) Knock-outs were missing on three quad outlet metal "J" boxes. One box was located on the wall by the drill press, one was located on the wall by the compressor and one was on the column by the center work bench by the grinder.
Recent events (3)
- — J (O) $0
- — C (S) $5975
- — Z (S) $5975
1910.303 F
- Issued
- May 8, 2017
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.303(f): Each disconnecting means for motors and appliances was not located and arranged so the purpose was evident, nor legibly marked to indicate its purpose: Location: Maintenance Shop, 500 Fenimore Road, Mamaroneck, NY 10543 On or about 11/14/16 a) The individual circuit breakers in the 110-volt sub panel were not labeled to indicate their purpose.
Recent events (3)
- — J (S) $9959
- — C (S) $9959
- — Z (S) $9959
1910.305 G01 IV
- Issued
- May 8, 2017
- Abate by
- Jun 2, 2017
- Penalty
- Initial $9,959 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): Location: Exterior of South Freezer, 500 Fenimore Road, Mamaroneck, NY 10543 On or about 11/14/16 a) An extension cord used to provide power to a PS 3000 Portable Weight Scale was used as a substitute for fixed wiring of the structure and was attached to a building surface.
Recent events (3)
- — J (S) $0
- — C (S) $9959
- — Z (S) $9959
More inspections at Arctic Glacier U.S.A., INC.
View Arctic Glacier U.S.A., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 312113)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342120706.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.