Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DAMIEN CONSTRUCTION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DAMIEN CONSTRUCTION, INC. in 512 E. GIRARD AVENUE, PHILADELPHIA, PA 19125 (NAICS 238140). OSHA activity number 342127164.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Damien Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Damien Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
512 E. GIRARD AVENUE
City
PHILADELPHIA
State
PA
ZIP
19125
Mailing
366 CHEYNEY ROAD, GLEN MILLS, PA 19342
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
14
Ownership type
A

3 citations on file for this inspection.

1926.451 F06

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 14, 2017
Penalty
Initial $5,070 · Current $5,070
29 CFR 1926.451(f)(6): The clearance between scaffolds and uninsulated power lines was not a minimum of 10 feet when scaffolds were erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines:   a) 512 E Girard Ave, Philadelphia, Pa - The employer did not ensure that the erected fabricated frame scaffold, approximately 40 feet high, 49 feet long and 5 feet wide, had clearance greater than 10 feet from the 13.2kv energized uninsulated power lines thus exposing the employees to electrocution hazards. This condition was observed on or about February 23, 2017.
Recent events (1)
  • — Z (S) $5070

1926.451 G04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 14, 2017
Penalty
Initial $5,070 · Current $5,070
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:  a) 512 E Girard Ave, Philadelphia, PA - The employer did not ensure that guardrails were installed on the ends of the erected fabricated frame scaffold, approximately 40 feet high, 49 feet long and 5 feet wide, thus exposing the employees to fall hazards. This condition was observed on or about February 23, 2017.
Recent events (1)
  • — Z (S) $5070

1926.100 A

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying object:  a) 512 E Girard Ave, Philadelphia, PA - The employer did not ensure employees, working on the ground level under the fabricated frame scaffold, wore head protection while employees worked above on scaffold placing brick thus exposing the employees to struck-by hazards. This condition was observed on or about February 23, 2017.
Recent events (1)
  • — Z (S) $0

View Damien Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342127164.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.