Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COMPO STEEL PRODUCTS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of COMPO STEEL PRODUCTS, INC. in 3647 N. HOLTON ST., MILWAUKEE, WI 53212 (NAICS 332313). OSHA activity number 342138351.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Compo Steel Products, INC. — free Get an email when a new federal OSHA severe-injury report for Compo Steel Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3647 N. HOLTON ST.
City
MILWAUKEE
State
WI
ZIP
53212
Mailing
3637 NORTH HOLTON STREET, MILWAUKEE, WI 53212
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332313
Employees
60
Ownership type
A

8 citations on file for this inspection.

1910.107 B03

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 18, 2017
Abate by
Aug 24, 2017
Penalty
Initial $3,555 · Current $2,000 Reduced
29 CFR 1910.107(b)(3): Floors. The floor surface of a spray booth and operator's working area, if combustible, shall be covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues.    (a) Pieces of combustible cardboard were used as floorcovering in the liquid spray booth.
Recent events (3)
  • — F (S) $2000
  • — C (S) $3555
  • — Z (S) $3555

1910.132 D01

Serious Gravity 1 2 instances 4 exposed
Issued
Aug 18, 2017
Abate by
Sep 7, 2017
Penalty
Initial $3,555 · Current $1,000 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:    (a) The employer did not adequately assess the workplace painting operations.  Paints containing isocyanate chemicals were not evaluated to determine dermal contact hazards.  Gloves used by the painter were not adequate to prevent dermal contact.
Recent events (3)
  • — F (S) $1000
  • — C (S) $3555
  • — Z (S) $3555

1910.133 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 18, 2017
Abate by
Aug 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) Employees using hand grinders on metal were not provided face shields to protect their face from flying particles.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 18, 2017
Abate by
Aug 24, 2017
Penalty
Initial $3,555 · Current $0 Reduced
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:    (a) On or about March 2, 2017, in the paint storage area two respirators not in use were openly stored on a workbench exposing them to contamination.
Recent events (3)
  • — F (S) $0
  • — C (S) $3555
  • — Z (S) $3555

1910.1026 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 18, 2017
Penalty
Initial $4,741 · Current $2,000 Reduced

Hazardous substances 0691

29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):    (a) Employees welding stainless steel were not evaluated as to their exposure to hexavalent chromium, a carcinogenic form of chromium created in the welding fumes.  The employer did not make this determination in accordance with neither paragraph (d)(2), the scheduled monitoring option, nor paragraph (d)(3), the performance-oriented option.
Recent events (3)
  • — F (S) $2000
  • — C (S) $4741
  • — Z (S) $4741

1910.1200 H01

Serious Gravity 1 2 instances 5 exposed
Issued
Aug 18, 2017
Abate by
Sep 7, 2017
Penalty
Initial $3,555 · Current $0 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    (a) Painters were not trained about paints containing isocyanates, a chemical  sensitizer that may cause dermatitis.     (b) Welders welding stainless steel were not trained about weld fumes containing hexavalent chromium, a carcinogen.
Recent events (3)
  • — F (S) $0
  • — C (S) $3555
  • — Z (S) $3555

1910.141 A03 I

Other-than-serious 1 instance 50 exposed
Issued
Aug 18, 2017
Abate by
Aug 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed:  (a) Surfaces in the lunchroom were contaminated with metal dusts.  The soda machine chute and chip vending machine chute were contaminated with dust containing cobalt, cadmium, and manganese.  This exposed employees to health illnesses affecting the kidneys, liver and other body systems.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Aug 18, 2017
Abate by
Sep 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a)  Employees used in house compressed air nozzle that was made of a piece of galvanized pipe and flattened at the discharge end, and was not designed to reduce compressed air pressure to less than 30 PSI.   (b)  Employees used in house made compressed air nozzle(s) located in the machine shop that were not designed to reduce compressed air pressure to less than 30 PSI.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Compo Steel Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342138351.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.