Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RUTTEN STRUCTURES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RUTTEN STRUCTURES, INC. in 28766 483RD AVENUE, CANTON, SD 57013 (NAICS 236115). OSHA activity number 342140860.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rutten Structures, INC. — free Get an email when a new federal OSHA severe-injury report for Rutten Structures, INC. is published. One employer, no account, unsubscribe in one click.
Site address
28766 483RD AVENUE
City
CANTON
State
SD
ZIP
57013
Mailing
47862 US HIGHWAY 18, CANTON, SD 57013
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
4
Ownership type
A

8 citations on file for this inspection.

1926.453 B02 V

Serious Gravity 10 1 instance 4 exposed
Issued
May 12, 2017
Abate by
Jun 8, 2017
Penalty
Initial $3,803 · Current $2,280 Reduced
29 CFR 1926.453(b)(2)(v): A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.    (a)  Rutten Construction, Inc. 28766 483rd Avenue in Canton, SD 57013: On and prior to February 27, 2017  the exposing employer did not ensure employees' use of a personal fall arrest or restraint system when performing work in an aerial lift. This condition exposed employees to fall hazards at a wide range of elevations.    Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e).
Recent events (2)
  • — I (S) $2280
  • — Z (S) $3803

1926.502 D17

Serious Gravity 10 1 instance 1 exposed
Issued
May 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(17): The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head.  (a)  Rutten Construction, Inc. 28766 483rd Avenue in Canton, SD 57013: On March 1, 2017 the exposing employer did not ensure an employee used the proper lanyard attachment point of a body harness. This condition exposed an employee to injury in the event of a fall.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
May 12, 2017
Abate by
Jun 8, 2017
Penalty
Initial $3,803 · Current $2,660 Reduced
29 CFR 1926.501(b)(13): Employees engaged in residential construction activities 6 feet or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):    (a)  Rutten Construction, Inc. 28766 483rd Avenue in Canton, SD 57013: On and prior to February 27, 2017 the exposing employer did not ensure employee use of fall protection systems when performing siding and roofing work from the multi-pitched roof of a residential structure. This condition exposed employees to fall hazards of approximately 13 feet.
Recent events (2)
  • — I (S) $2660
  • — Z (S) $3803

1926.503 A01

Serious Gravity 10 1 instance 4 exposed
Issued
May 12, 2017
Abate by
Jun 8, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  (a)  Rutten Construction, Inc. 28766 483rd Avenue in Canton, SD 57013: On and prior to February 27, 2017 the exposing employer did not ensure employees received a training program that would allow them to identify fall hazards and provide means to mitigate fall hazards.  This condition exposed employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 B01

Serious Gravity 10 1 instance 4 exposed
Issued
May 12, 2017
Abate by
Jun 8, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  (a) Rutten Construction, Inc. 28766 483rd Avenue in Canton, SD 57013: On and prior to February 27, 2017 the exposing employer did not complete fall hazard training for employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B14

Serious Gravity 10 1 instance 4 exposed
Issued
May 12, 2017
Abate by
Jun 8, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system:  (a)  Rutten Construction, Inc. at 28766 483rd Avenue in Canton, SD 57013: On and prior to February 27, 2017 the exposing employer did not ensure the second level window opening approximately 30 inches from floor level was appropriately guarded with a top rail. This condition exposed employees to fall hazards of approximately 13 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 B01

Serious Gravity 1 1 instance 4 exposed
Issued
May 12, 2017
Abate by
Jun 8, 2017
Penalty
Initial $1,630 · Current $1,000 Reduced
29 CFR 1910.29(b)(1): The top edge height of top rails, or equivalent guardrail system members, are 42 inches, plus or minus 3 inches, above the walking-working surface.  The top edge height may exceed 45 inches, provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D-11):    (a)  Rutten Construction, Inc. 47862 US Highway 18 in Canton, SD 57013: On and prior to February 27, 2017 the exposing employer did not ensure the shop mezzanine pony wall had an appropriate top edge height. This condition exposed employees were to fall hazards of approximately 9 feet.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1630

1910.178 L06

Other-than-serious 1 instance 4 exposed
Issued
May 12, 2017
Abate by
Jun 8, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l):  (a)  Rutten Construction, Inc. 28766 483rd Avenue in Canton, SD 57013: On and prior to February 27, 2017 the employer did not complete a certificate of training for powered industrial truck operators.     Note: The requirements applicable to construction work under this paragraph are identical to those set forth in 1910.178(i)
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Rutten Structures, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342140860.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.