OSHA Inspection: FREUDENBERG-NOK GENERAL PARTNERSHIP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FREUDENBERG-NOK GENERAL PARTNERSHIP in 6 AXLE DR., TILTON, NH 03276 (NAICS 441310). OSHA activity number 342142239.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Freudenberg-Nok General Partnership — free Get an email when a new federal OSHA severe-injury report for Freudenberg-Nok General Partnership is published. One employer, no account, unsubscribe in one click.
Site address
6 AXLE DR.
City
TILTON
State
NH
ZIP
03276
Mailing
6 AXLE DR., TILTON, NH 03276
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
Employees
240
Ownership type
A

2 citations on file for this inspection.

1904.29 B01

Other-than-serious 1 instance 1 exposed
Issued
Jul 3, 2017
Abate by
Aug 7, 2017
Penalty
Initial $1,693 · Current $1,185 Reduced
29 CFR 1904.29(b)(1): A Log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent), was not completed in the detail as required by the regulation:  a. Site - On or about January 27, 2017, the employer failed to complete the OSHA Form 300 or equivalent in the detail required by the regulation.  For Case No. 2017-01, Column (F) did not include a description of what object or substance that directly injured or made the person ill, Column (L) did not include the number of days, and Column (M) was not checked with the appropriate injury or illness type.
Recent events (2)
  • — I (O) $1185.1
  • — Z (O) $1693

1910.303 G01 II

Other-than-serious 2 instances 1 exposed
Issued
Jul 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   a. Loading Dock- On or about March 2, 2017, the space in front of two Square D Heavy Duty Safety Switches labeled " Dock Leveler P2 #22 480V" were not maintained and were obstructed by materials including a pallet jack, forklift, and the charging station, thus impeding quick access to the electrical switches.  The switches were used to turn power on and off for two Kelly dock levelers. b. Loading Dock- On or about March 2, 2017, the space in front of two Square D General Duty Safety Switches were not maintained and were obstructed by materials including a pallet jack, forklift, and the charging station, thus impeding quick access to the electrical switches.  The switches were used to turn power on and off for two Dok-Lok vehicle restraints.