Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: BEN WEITSMAN & SON OF SYRACUSE LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BEN WEITSMAN & SON OF SYRACUSE LLC in 333 BRIDGE STREET, SOLVAY, NY 13209 (NAICS 423930). OSHA activity number 342143229.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BEN Weitsman & SON of Syracuse LLC for free Get an email when a new federal OSHA severe-injury report for BEN Weitsman & SON of Syracuse LLC is published. One employer, no account, unsubscribe in one click.
Site address
333 BRIDGE STREET
City
SOLVAY
State
NY
ZIP
13209
Mailing
15 WEST MAIN STREET, OWEGO, NY 13827
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
20
Ownership type
A

7 citations on file for this inspection.

1910.106 E02 IV B

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2017
Abate by
Aug 28, 2017
Penalty
Initial $6,338 · Current $4,120 Reduced
29 CFR 1910.106(e)(2)(iv)(b): Where flammable liquids are used or handled, except in closed containers, there were no means provided to dispose promptly and safely of leakage or spills:    a) On or about 3/1/2017, At the car reclamation area: Gasoline was allowed to accumulate in the bottom of the Enviro Rack reclamation unit while employees were working directly above the pooled gasoline.      Abatement certification is required for this item.
Recent events (2)
  • · I (S) $4119.7
  • · Z (S) $6338

1910.106 E02 IV D

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2017
Abate by
Aug 28, 2017
Penalty
Initial $6,338 · Current $4,120 Reduced
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve. Transferring by means of air pressure on the container or portable tanks was not prohibited:    a) On or before 3/1/2017, At the car reclamation area:  Employees were transferring gasoline between containers by the use of compressed air.      Abatement certification is required for this item.
Recent events (2)
  • · I (S) $4119.7
  • · Z (S) $6338

1910.106 E06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2017
Abate by
Aug 28, 2017
Penalty
Initial $6,338 · Current $4,120 Reduced
29 CFR 1910.106(e)(6)(i):  Adequate precautions were not taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:    a) On or about 3/1/2017, At the car reclamation area: Employees reclaiming flammable liquids such as gasoline were utilizing a metal spike to perforate metal and plastic gasoline tanks mounted on vehicles.      Abatement certification is required for this item.
Recent events (2)
  • · I (S) $4119.7
  • · Z (S) $6338

1910.106 E06 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2017
Abate by
Jul 5, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the containers:  a) On or about 3/1/2017, At the car reclamation area: Employees were transferring gasoline from vehicle mounted tanks to pad mounted tanks.  No bonding was in use.    b) On or before 3/1/2017, At the car reclamation area:  Employees were transferring gasoline between containers without bonding the containers.    Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.106 E07 I B

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2017
Abate by
Aug 28, 2017
Penalty
Initial $6,338 · Current $4,120 Reduced
29 CFR 1910.106(e)(7)(i)(b): Locations where flammable vapor-air mixtures exist under normal operations were not classified Class I, Division 1 five feet in all directions from all points of vapor liberation:    a) On or about 3/1/2017, At the car reclamation area: Employees were utilizing an electric drill, extension cord, and refrigerant reclamation unit within five feet of the "Enviro Rack" reclamation system and vehicle mounted gasoline tanks.      Abatement certification is required for this item.
Recent events (2)
  • · I (S) $4119.7
  • · Z (S) $6338

1910.307 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2017
Abate by
Jul 5, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.307(c)(2): 29 CFR 1910.307(c)(2): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not safe for the hazardous (classified location), nor approved for the hazardous (classified) location or the ignitable or combustible properties of the specific gas, vapor, dust or fiber that was present:  a) On or about 3/1/2017, At the car reclamation area: Employees were utilizing an electric drill, extension cord, and refrigerant reclamation unit within five feet of the "Enviro Rack" reclamation system and vehicle mounted gasoline tanks.  The electrical equipment was not rated for Class 1 Div1 use.  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.138 A

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2017
Abate by
Aug 28, 2017
Penalty
Initial $6,338 · Current $4,120 Reduced
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes:    a) On or before 3/1/2017, At the car reclamation area:  Employees were utilizing cotton gloves which were repeatedly soaked with gasoline.     Abatement certification is required for this item.
Recent events (2)
  • · I (S) $4119.7
  • · Z (S) $6338

View BEN Weitsman & SON of Syracuse LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342143229.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.