OSHA Inspection: INTER CONTRACTING CORP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INTER CONTRACTING CORP in SOUTH-WEST CORNER OF 9TH AVE & 119ST STREET, COLLEGE POINT, NY 11356 (NAICS 237310). OSHA activity number 342144524.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inter Contracting Corp — free Get an email when a new federal OSHA severe-injury report for Inter Contracting Corp is published. One employer, no account, unsubscribe in one click.
Site address
SOUTH-WEST CORNER OF 9TH AVE & 119ST STREET
City
COLLEGE POINT
State
NY
ZIP
11356
Mailing
274 WHITE PLAINS ROAD, SUITE 6, EASTCHESTER, NY 10709
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
30
Ownership type
A

2 citations on file for this inspection.

1926.651 I01

Other-than-serious 1 instance 1 exposed
Issued
Jun 12, 2017
Abate by
Jun 16, 2017
Penalty
Initial $6,464 · Current $6,464
29 CFR 1926.651(i)(1): Where the stability of adjoining buildings, walls, or other structures was endangered by excavation operations, support systems such as shoring, bracing or underpinning was not provided to ensure the stability of such structures for the protection of employees:    A)     On or about 02/27/2017, at the South-West corner of 9th Ave & 119th Street, Whitestone, NY       Employee working inside of a trench measuring 5'W x 8'L x 5-1/2'D, near the east wall, was not protected from unstable structures.  A piece of asphalt fell from the trench wall, underneath the metal plate, and struck an employee.    ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (O) $6464
  • — Z (S) $6464

1926.652 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jun 12, 2017
Abate by
Jun 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c):  A)    On or about 02/27/2017, at the South-West corner of 9th Ave & 119th Street, Whitestone, NY     An employee was shoveling dirt in a trench measuring 5'W x 8'L x 5-1/2'D to expose a gas line was not provided with cave-in protection while working.  ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.