WASHINGTON, DC ·
OSHA Inspection: EDGAR'S MASONRY CONSTRUCTION INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of EDGAR'S MASONRY CONSTRUCTION INC. in 1245 I STREET NE, WASHINGTON, DC 20002 (NAICS 238140). OSHA activity number 342165305.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDGAR'S MASONRY CONSTRUCTION INC.
- Site address
- 1245 I STREET NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20002
- Mailing
- 3414 GROVETON STREET, ALEXANDRIA, VA 22306
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 7
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.451 B02
- Issued
- May 3, 2017
- Abate by
- May 9, 2017
- Penalty
- Initial $4,183 · Current $2,468 Reduced
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) Front, Left Side of House - Three workers were re-pointing bricks on the outside second level of the structure from an approximate 10 inch wide scaffold platform, 15 feet above the ground, on or about 3/9/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $2468
- · Z (S) $4183
1926.451 C02 II
- Issued
- May 3, 2017
- Abate by
- May 9, 2017
- Penalty
- Initial $4,183 · Current $2,468 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a) Left Side Front of House - A 20' aluminum extension ladder was tied to the structure's chimney and suspended down the front of the house to support a platform/plank that had been extended from a scaffolding outrigger, on or about 3/9/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $2468
- · Z (S) $4183
1926.451 G01 VII
- Issued
- May 3, 2017
- Abate by
- May 9, 2017
- Penalty
- Initial $4,183 · Current $2,468 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Front Left Side of House - Two workers were standing and one worker was sitting on a one plank scaffolding system approximately 15 feet high that was missing a mid-rail, on or about 3/9/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $2468
- · Z (S) $4183
1926.1053 B04
- Issued
- May 3, 2017
- Abate by
- May 9, 2017
- Penalty
- Initial $4,183 · Current $2,468 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Front Left Side of Structure - A 20 foot extension ladder was tied to the chimney of the house, then suspended down the front of the house and used to support one end of a scaffolding plank, 15 feet above ground, from which the workers were re-pointing bricks and a scaffolding plank at the bottom of the ladder, on or about 3/09/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $2468
- · Z (S) $4183
1926.451 E01
- Issued
- May 3, 2017
- Abate by
- May 9, 2017
- Penalty
- Initial $8,366 · Current $4,936 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Front Center of Structure - Workers gained access to the upper levels of the scaffolding by climbing the scaffolding frame and cross braces, on or about 3/9/2017. Edgar's Masonry Construction Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.451(e)(1), which was contained in OSHA inspection number 571939, citation number 1, item number 2 and was affirmed as a final order on 11/09/2012, with respect to a workplace located at 4538 Cathedral Ave NW Washington DC 20008. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (R) $4936
- · Z (R) $8366
More inspections at Edgar'S Masonry Construction INC.
View Edgar'S Masonry Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in DC