BLAINE, WA —
OSHA Inspection: U.S. CUSTOMS AND BORDER PROTECTION, BLAINE STATION BORDER PATROL
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of U.S. CUSTOMS AND BORDER PROTECTION, BLAINE STATION BORDER PATROL in 1590 H STREET, BLAINE, WA 98230 (NAICS 928110). OSHA activity number 342171824.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 1590 H STREET
- City
- BLAINE
- State
- WA
- ZIP
- 98230
- Mailing
- 1590 H STREET, BLAINE, WA 98230
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 83
- Ownership type
- D
Citations
4 citations on file for this inspection.
1910.334 A02 I
- Issued
- Mar 28, 2017
- Abate by
- May 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) Tool Shed, where the outer sheathing on power cord to the Sparton Technology Monitron was damaged and missing portions that exposed insulated conductors.
Recent events (1)
- — Z (S) $0
1910.334 A02 II
- Issued
- Mar 28, 2017
- Abate by
- May 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed employee(s) to injury and the defective or damaged item was not removed from service: a) Tool Shed, where the outer sheathing on power cord to the Sparton Technology Monitron was damaged and missing portions that exposed insulated conductors.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Mar 28, 2017
- Abate by
- May 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling: a) Facility, where electrical equipment not used as listed or labeled included: 1. Tool Shed, where the Tripp Lite relocatable power tap was used to supply power to the Wilton 6 inch bench grinder. 2. Annex Building, where the APC relocatable power tap located beneath the Elkay drinking fountain was permanently mounted to the wall and the power cord was run through an unprotected hole in the metal plate on the bottom of the drinking fountain; the APC relocatable power tap used to supply power to audio visual and computer equipment. The U.S. Customs & Border Protection Border Patrol was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 1149914, citation number 2, item number 1 and was affirmed as a final order on July 21, 2016, with respect to a workplace located at Blaine, WA. The U.S. Customs & Border Protection Border Patrol was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 977497, citation number 2, item number 1 and was affirmed as a final order on July 7, 2014, with respect to a workplace located at Ferndale, WA. The U.S. Customs & Border Protection Border Patrol was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 242715, citation number 2, item number 1 and was affirmed as a final order on April 4, 2012, with respect to a workplace located at Bellingham, WA.
Recent events (1)
- — Z (R) $0
1904.29 B06
- Issued
- Mar 28, 2017
- Abate by
- May 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(b)(6): The employer did not enter "privacy case" in the space normally used for the employee's name on the OSHA 300 form or equivalent as required by paragraphs (b)(6)-(b)(7)(vi) of this section: a) Facility, where case number 2014-05413 on the OSHA 300 log for calendar year 2014 was not entered as a privacy case.
Recent events (1)
- — Z (O) $0
More inspections at U.S. Customs and Border Protection, Blaine Station Border Patrol
View U.S. Customs and Border Protection, Blaine Station Border Patrol's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342171824.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.