Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KG ROOFING & RESTORATION, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KG ROOFING & RESTORATION, INC in 717 ROGERS ST., DOWNERS GROVE, IL 60515 (NAICS 238160). OSHA activity number 342175437.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KG Roofing & Restoration, INC — free Get an email when a new federal OSHA severe-injury report for KG Roofing & Restoration, INC is published. One employer, no account, unsubscribe in one click.
Site address
717 ROGERS ST.
City
DOWNERS GROVE
State
IL
ZIP
60515
Mailing
2432 W ERIE APT 3, CHICAGO, IL 60612
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Apr 19, 2017
Abate by
May 3, 2017
Penalty
Initial $5,070 · Current $3,500 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):        On or about March 16, 2017, the employer did not ensure employees were protected from a fall while performing the following work activities, exposing employees to a fall of over 25 feet.     a)  Employees performing roofing activities on a residential property were exposed to fall while working without fall protection.     b)  Employees walking on the rafters of a  residential property were exposed to fall while working without fall protection.     Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5070

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 19, 2017
Abate by
May 3, 2017
Penalty
Initial $2,897 · Current $1,500 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:     On or about March 16, 2017, employees used an "A" frame step ladder that did not extend three feet past the attic they were accessing, exposing the employee to a fall of 10 feet.      Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2897

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 19, 2017
Abate by
May 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:   On or about March 16, 2017, employees used an A frame portable ladder in the closed position, exposing employees to the hazards associated with using a ladder for purposes other than intended.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B16

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 19, 2017
Abate by
May 3, 2017
Penalty
Initial $2,898 · Current $0 Reduced
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired.     On or about March 16, 2017, employees used a portable ladder with structural damage, exposing employees to the hazards associated with using a damaged ladder.     Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2898

View KG Roofing & Restoration, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342175437.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.