PENNSAUKEN, NJ ·
OSHA Inspection: UNIFIED DOOR AND HARDWARE GROUP, LLC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of UNIFIED DOOR AND HARDWARE GROUP, LLC. in 1650 SUCKLE HIGHWAY, PENNSAUKEN, NJ 08110 (NAICS 423710). OSHA activity number 342175478.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIFIED DOOR AND HARDWARE GROUP, LLC.
- Site address
- 1650 SUCKLE HIGHWAY
- City
- PENNSAUKEN
- State
- NJ
- ZIP
- 08110
- Mailing
- 1650 SUCKLE HIGHWAY, PENNSAUKEN, NJ 08110
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423710
- Employees
- 150
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.213 H01
- Issued
- Sep 5, 2017
- Abate by
- Oct 10, 2017
- Penalty
- Initial $8,149 · Current $4,892 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saws were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the stock being cut. a) Unified Door and Hardware Group LLC. - Wood working area: Two De Walt Radial Arm Saws did not have a guard on the lower exposed portion of the blade to enclose and automatically adjust the full diameter of the blade , observed on or about 03/16/2017.
Recent events (2)
- · I (S) $4892
- · Z (S) $8149
1910.242 B
- Issued
- Sep 5, 2017
- Abate by
- Sep 29, 2017
- Penalty
- Initial $4,889 · Current $2,932 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. a) Unified Door and Hardware G: Compressed Group LLC. - Throughout the manufacturing area: The compressed air is use for cleaning purposes by employees at approximately 115 p.s.i., observed on or about 03/16/2017.
Recent events (2)
- · I (S) $2932
- · Z (S) $4889
1910.303 G01 II
- Issued
- Sep 5, 2017
- Abate by
- Sep 29, 2017
- Penalty
- Initial $4,889 · Current $2,932 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) Unified Door and Hardware Group LLC. - Throughout the production areas: Access to electrical panels was obstructed by equipment and materials . Observed on or about 03/16/2017.
Recent events (2)
- · I (S) $2932
- · Z (S) $4889
More inspections at Unified Door and Hardware Group, LLC.
View Unified Door and Hardware Group, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 423710)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342175478.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.