BOULDER CITY, NV —
OSHA Inspection: NATIONAL PARK SERVICE, LAKE MEAD NATIONAL RECREATION AREA - MAINTENANCE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE, LAKE MEAD NATIONAL RECREATION AREA - MAINTENANCE in 101 KATZENBACH DRIVE, BOULDER CITY, NV 89005 (NAICS 712190). OSHA activity number 342213634.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 101 KATZENBACH DRIVE
- City
- BOULDER CITY
- State
- NV
- ZIP
- 89005
- Mailing
- 601 NEVADA WAY, BOULDER CITY, NV 89005
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712190
- Employees
- 30
- Ownership type
- D
Citations
7 citations on file for this inspection.
1910.101 B
- Issued
- Aug 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks was not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6: (a) Roads and Trails Tool Room Flammable Cabinet: Employees were exposed to fire and explosion hazards while storing two 14.1 Ounce BenzOMatic Propane Fuel Cylinders with flammable and combustible material such as, but not limited to, Gunk Engine Degreaser, Kingsford Charcoal Fluid and ChemSearch Degreaser and Motor Cleaner in the same flammable storage cabinet. (b) Electrical Shop Flammable Cabinet: Employees were exposed to fire and explosion hazards while storing one 16 Ounce TurboTorch Mapp Gas Cylinders with flammable and combustible material such as, but not limited to, approximately six 16 Ounce aerosol cans of WD-40, approximately twelve cans of 5.75 Ounce cans of Permatex Battery Cleaner and approximately 24 cans of Krylon Spray Paint in the same flammable storage cabinet. THE DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, GRAND CANYON FACILITY MANAGEMENT DIVISION WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 994371, CITATION 01, ITEM NUMBER 003 AND WAS AFFIRMED AS A FINAL ORDER ON FEBRUARY 4, 2015, WITH RESPECT TO A WORKPLACE LOCATED AT BUILDING 1575, SHUTTLE BUS ROAD, GRAND CANYON, ARIZONA 86023.
Recent events (1)
- — Z (R) $0
1910.151 C
- Issued
- Aug 30, 2017
- Abate by
- Sep 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Battery Charger Room: Employees are exposed to injuries to eyes and face from the ZEE Protector I, Primary Eye Wash Station (#0643) that was not readily available for use in that the path of travel from the hazard to the equipment was not free of obstructions and inoperable by being empty when working on adding sulfuric acid and/or distilled water to lead/acid batteries. THE DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, CHANNEL ISLANDS NATIONAL PARK WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 913241, CITATION 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON NOVEMBER 12, 2013, WITH RESPECT TO A WORKPLACE LOCATED AT WOLVERTON WATER, SEQUOIA NATIONAL PARK, CALIFORNIA 93262.
Recent events (1)
- — Z (R) $0
1910.213 C02
- Issued
- Aug 30, 2017
- Abate by
- Sep 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: Carpenter Shop: Employees are exposed to an impalement hazard by using Delta Rockwell 34-395 143 Table Saw without kickback dogs to prevent the wood from hurtling toward the operator if the blade pinches or binds during the ripping cut of plywood or baseboards. THE U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1056725, CITATION 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 1, 2016, WITH RESPECT TO A WORKPLACE LOCATED AT U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, GREAT BASIC NATIONAL PARK, CARPENTER SHOP, 100 GREAT BASIN NATIONAL PARK, BAKER, NEVADA 89311.
Recent events (1)
- — Z (R) $0
1910.213 C03
- Issued
- Aug 30, 2017
- Abate by
- Sep 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: Carpenter Shop: Employees are exposed to an impalement hazard by using Delta Rockwell 34-395 143 Table Saw without kickback dogs to prevent the wood from hurtling toward the operator if the blade pinches or binds during the ripping cut of plywood or baseboards. THE U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1056725, CITATION 01, ITEM NUMBER 002 AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 1, 2016, WITH RESPECT TO A WORKPLACE LOCATED AT U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, GREAT BASIC NATIONAL PARK, CARPENTER SHOP, 100 GREAT BASIN NATIONAL PARK, BAKER, NEVADA 89311.
Recent events (1)
- — Z (R) $0
1910.242 B
- Issued
- Aug 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment: (a) Roads and Trails Bay: Employees were exposed to flying parts and pieces and air embolisms while using an air nozzle with approximately 60 p.s.i. of unregulated air at the nozzle. (b) Carpenter Shop: Employees were exposed to flying parts and pieces and air embolisms while using an air nozzle with approximately 90 p.s.i. of unregulated air at the nozzle. THE U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1165213, CITATION 01, ITEM NUMBER 002 AND WAS AFFIRMED AS A FINAL ORDER ON OCTOBER 6, 2016, WITH RESPECT TO A WORKPLACE LOCATED AT U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, SEQUOIA AND KINGS CANYON, WOLVERTON WATER TREATMENT FACILITY, SEQUOIA NATIONAL PARK, CALIFORNIA 93262.
Recent events (1)
- — Z (R) $0
1910.303 B02
- Issued
- Aug 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Budget Office: Employees are exposed to electric shock/fire by using a Holmes 1500-Watt Slim Profile Heater Fan, Model HFH441-NU attached to a Relocatable Power Tap. (b) Budget Office: Employees are exposed to electric shock/fire by using a GE Spacemaker Compact Refrigerator Model GCE06GSHSB attached to a Relocatable Power Tap. (c) Facility Management Software System (FMSS) Lead Office: Employees are exposed to electric shock/fire by using a Maxi-Heat Ceramic Fan Heater Model: CH115B attached to a flexible cord. THE U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 992665, CITATION 01, ITEM NUMBER 005 AND WAS AFFIRMED AS A FINAL ORDER ON FEBRUARY 2, 2015, WITH RESPECT TO A WORKPLACE LOCATED AT U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, GRAND CANYON, VISITOR AND RESOURCE PROTECTION STATION, ONE THREE CLINIC ROAD, GRAND CANYON, ARIZONA 86023.
Recent events (1)
- — Z (R) $0
1910.305 J02 IV
- Issued
- Aug 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: (a) Men's Restroom: Employees were exposed to electric shock/fire hazards due to electrical outlet located above a sink that was not protected by GFCI. (b) Warehouse: Employees were exposed to electric shock/fire hazards due to Elkay Enhanced EZH2O Bottle Filling Station Model LZS8WSLP connected to an electrical outlet connected that was not protected by GFCI. THE U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1086115, CITATION 01, ITEM NUMBER 006 AND WAS AFFIRMED AS A FINAL ORDER ON NOVEMBER 10, 2015, WITH RESPECT TO A WORKPLACE LOCATED AT U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, 1 BLACK CANYON ROAD, ESSEX, CALIFORNIA 92332
Recent events (1)
- — Z (R) $0
More inspections at National Park Service, Lake Mead National Recreation Area - Maintenance
More inspections in this industry (NAICS 712190)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342213634.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.