Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: ORION DRILLING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ORION DRILLING, LLC in LEASER COVINGTON 46, PECOS, TX 79772 (NAICS 213111). OSHA activity number 342233251.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Orion Drilling, LLC for free Get an email when a new federal OSHA severe-injury report for Orion Drilling, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ORION DRILLING, LLC
Site address
LEASER COVINGTON 46
City
PECOS
State
TX
ZIP
79772
Mailing
674 FLATO RD, CORPUS CHRISTI, TX 78405
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
11
Ownership type
Private (A)

4 citations on file for this inspection.

1910.22 D01

Other-than-serious 1 instance 3 exposed
Issued
Sep 15, 2017
Abate by
Oct 13, 2017
Penalty
Initial $3,802 · Current $3,000 Reduced
29 CFR 1910.22(d)(1): Walking-working surfaces were not inspected, regularly, and maintained in a safe condition.    Drill site: On or about April 05, 2017, at the mud tank, employees were exposed to uneven walking-working surface due to a metal sensor floor cap being lifted approximately 3-inches above the surface. This condition exposed employees to trip hazards.
Recent events (2)
  • · I (O) $3000
  • · Z (S) $3802

1910.212 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 15, 2017
Abate by
Oct 13, 2017
Penalty
Initial $3,802 · Current $3,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts:    Drill site: On or about April 05, 2017, the draw-works on the rig floor was not provided with a guard to protect employees from hazards such as those created by point of operation, ingoing nip points, rotating parts. This condition exposed employees to caught-in hazards.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $3802

1910.305 G02 III

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 15, 2017
Abate by
Oct 13, 2017
Penalty
Initial $7,605 · Current $5,000 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to the joints or terminal screws:    Drill site: On or about April 05, 2017, the power cord to the air compressor 46 located in generator power house did not have an effective strain relief device.  This condition exposed employees to electrical shock hazards.    Orion Drilling Company, LLC was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.305(g)(2)(iii), which was contained in OSHA inspection number 961038, citation number 1, item number 3 and was affirmed as a final order on 04/21/2014, with respect to a workplace located at S. of CR 405 on FM 1680, Markers 1-H Well, Flatonia, TX 78941.
Recent events (2)
  • · I (S) $5000
  • · Z (R) $7605

1910.305 B01 II

Other-than-serious 1 instance 8 exposed
Issued
Sep 15, 2017
Abate by
Oct 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:     Drill site: On or about April 05, 2017, the air conditioning unit condenser electrical control box  outside the tool pusher's trailer had an unused opening. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Orion Drilling, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342233251.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.