Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEORGIA BUILDERS LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of GEORGIA BUILDERS LLC in 4022 GEORGIA AVE., NW, WASHINGTON, DC 20011 (NAICS 236116). OSHA activity number 342239100.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Georgia Builders LLC — free Get an email when a new federal OSHA severe-injury report for Georgia Builders LLC is published. One employer, no account, unsubscribe in one click.
Site address
4022 GEORGIA AVE., NW
City
WASHINGTON
State
DC
ZIP
20011
Mailing
4132 GEORGIA AVENUE NW, WASHINGTON, DC 20011
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 25, 2017
Penalty
Initial $2,716 · Current $2,716
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights:   a)  Scaffold, East Exposure - On or about 01/18/2017, a stucco mechanic was exposed to a 50 foot fall from a scaffold platform which was not fully planked between the scaffold's vertical uprights.    No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $2716

1926.451 C01 II

Serious Gravity 5 1 instance 2 exposed
Issued
May 25, 2017
Abate by
Jun 1, 2017
Penalty
Initial $2,716 · Current $2,716
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed  according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91m) wide:    a)  Scaffold, East Side of Building - On or about 01/18/2017, workers were exposed to a potential scaffold collapse from two fabricated frame scaffold towers which were 5 feet wide at their bases, 50 feet high and each secured with only a singe board located approximately at only 15 feet above each scaffold's base.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $2716

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
May 25, 2017
Abate by
Jun 1, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:   a)  Scaffold, East Side of Building - On or about 01/18/2017, workers were exposed to a 40 foot fall from the cross braces and frames of a fabricated frame scaffold while climbing up the scaffold components in order to access an elevated work platform.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.