Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NABORS DRILLING USA LP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NABORS DRILLING USA LP in RIG 887 GRIM REAPER 2930, WELL 1H, 22.4 MILES NW FROM FORT STOCKTON, TX, FORT STOCKTON, TX 79735 (NAICS 213111). OSHA activity number 342240322.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nabors Drilling USA LP — free Get an email when a new federal OSHA severe-injury report for Nabors Drilling USA LP is published. One employer, no account, unsubscribe in one click.
Site address
RIG 887 GRIM REAPER 2930, WELL 1H, 22.4 MILES NW FROM FORT STOCKTON, TX
City
FORT STOCKTON
State
TX
ZIP
79735
Mailing
2500 WEST OREGON, ODESSA, TX 79764
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
11
Ownership type
A

2 citations on file for this inspection.

1910.305 A02 X

Deleted Serious Gravity 5 1 instance 11 exposed
Issued
Aug 11, 2017
Abate by
Aug 30, 2017
Penalty
Initial $7,967 · Current $0 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.  Parts Trailer: On or about April 4, 2017 flexible cords were not protected against accidental damage from doorways and sharp corners. This condition exposed employees to an electrical shock hazard.
Recent events (3)
  • — F (S) $0
  • — C (S) $7967
  • — Z (S) $7967

1910.305 A02 IX

Deleted Other-than-serious 1 instance 3 exposed
Issued
Aug 11, 2017
Abate by
Aug 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination shall be protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded.  Mixing Area: On or about April 4, 2017, the guard that protects the lamps in the mixing area was broken leaving the light bulbs exposed to accidental contact or breakage. This condition exposed employees to a struck-by hazard.