GIBSON CITY, IL —
OSHA Inspection: SOLAE, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SOLAE, LLC in 124 S. ROUTE 47, GIBSON CITY, IL 60936 (NAICS 311222). OSHA activity number 342242542.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOLAE, LLC
- Site address
- 124 S. ROUTE 47
- City
- GIBSON CITY
- State
- IL
- ZIP
- 60936
- Mailing
- PO BOX 112, GIBSON CITY, IL 60936
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311222
- Employees
- 145
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.25 B03
- Issued
- May 12, 2017
- Abate by
- Jun 13, 2017
- Penalty
- Initial $7,243 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.25(b)(3): The employer did not ensure that the stairs had uniform riser heights and tread depths between the landings: On or about April 11, 2017, the employer provided stairs to the second floor above Extruder 2 and the employees were exposed to fall hazards and the employer did not ensure the stairs had uniform riser heights: a) 7.25-inches between step 4 and step 5; b) 6.5-inches between step 5 to step 6; c) 9-inches between step 6 to step 7; and d) 7.25-inches between step 7 and step 8.
Recent events (2)
- — I (O) $2000
- — Z (S) $7243
1910.147 C04 II B
- Issued
- May 12, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $5,432 · Current $5,432
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about April 6, 2017, the employer's lockout program did not list specific sources of hazardous energy but did list specific instructions for control of these sources.
Recent events (2)
- — I (S) $5432
- — Z (S) $5432
1910.147 D03
- Issued
- May 12, 2017
- Abate by
- Jun 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: On or about April 6, 2017, employees were exposed to pinch-point hazards when unjamming the Unground System and a rod is used at the 2-inch cleanout opening to move plugged material at the rotary vein airlock and the employer did not ensure the electrical energy for the blower (480V) and airlock (480V) were isolated prior to unjamming the material ahead of the airlock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Solae, LLC
View Solae, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311222)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342242542.