SAINT JOHNS, FL —
OSHA Inspection: HERNANDEZ DRYWALL, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HERNANDEZ DRYWALL, LLC in 88 MIRINDA PLACE, SAINT JOHNS, FL 32259 (NAICS 238140). OSHA activity number 342246394.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HERNANDEZ DRYWALL, LLC
- Site address
- 88 MIRINDA PLACE
- City
- SAINT JOHNS
- State
- FL
- ZIP
- 32259
- Mailing
- 3200 HARTLEY RD APT 181, JACKSONVILLE, FL 32257
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.501 B13
- Issued
- Aug 3, 2017
- Penalty
- Initial $4,346 · Current $2,608 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about April 11, 2017, on the 4:12 pitch roof on the right side of the house, two employees installing lathing were exposed to an 11 feet fall hazard from the eave in that they were not protected by a fall protection system.
Recent events (2)
- — I (S) $2607.5
- — Z (S) $4346
1926.1053 B01
- Issued
- Aug 3, 2017
- Penalty
- Initial $4,346 · Current $2,608 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about April 11, 2017, on the right side of the house, the roof access ladder did not extend 3 feet above the roof eave at the upper landing surface of the roof, exposing lathing installation employees to an 11 feet fall hazard.
Recent events (2)
- — I (S) $2607.5
- — Z (S) $4346
1926.1053 B04
- Issued
- Aug 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a. On or about April 11, 2017, on the right side of the 4:12 pitch first-story roof, a folded step ladder was leaned against the second-story wall, and it was used to install lathing on the upper areas of that wall, exposing employees to a 15 feet fall hazard over the eave. b. On or about April 11, 2017, on the left side of the 4:12 pitch first story roof, a folded step ladder was leaned against the second-story wall, and it was used to install lathing on the upper areas of that wall, exposing employees to an 11 feet fall hazard over the eave.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B06
- Issued
- Aug 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(6): Ladders were used on surfaces which were not stable and level: a. On or about April 11, 2017, on the right rear of the 4:12 pitch first-story roof the feet of a step ladder were placed down the slope of the roof in an unstable manner exposing an employee on the step ladder to a 15 feet fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 A01
- Issued
- Aug 3, 2017
- Abate by
- Aug 22, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. On or about April 11, 2017, employees installing lathing from elevations where they were exposed to fall hazards had not been trained to select and install appropriate anchor systems for personal fall protection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1053 B16
- Issued
- Aug 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: A. On or about April 11, 2017, on the left side of the house, a 20-foot Werner aluminum extension ladder had a broken foot on the bottom of the right base section rail, and it had not been removed from service.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Hernandez Drywall, LLC
View Hernandez Drywall, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342246394.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.