OSHA Inspection: COAST GUARD EXCHANGE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COAST GUARD EXCHANGE in BUILDING 26 USCG-BSU, KODIAK, AK 99619 (NAICS 452111). OSHA activity number 342256005.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coast Guard Exchange — free Get an email when a new federal OSHA severe-injury report for Coast Guard Exchange is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 26 USCG-BSU
City
KODIAK
State
AK
ZIP
99619
Mailing
US COAST GUARD BASE/PO BOX 195014, KODIAK, AK 99619
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452111
Employees
24
Ownership type
D

7 citations on file for this inspection.

1910.37 A04

Serious Gravity 10 1 instance 3 exposed
Issued
May 3, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times.  Building 26, warehouse, walk-in freezer; on or about 13 April 2017 and times prior thereto; the emergency escape plunger on the interior side of the walk-in freezer door was inoperative. Emergency escape plunger will not cycle preventing egress. This condition exposed employees to an entrapment hazard.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 24 exposed
Issued
May 3, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  Building 26, Sporting goods area; on or about 13 April 2017 and times prior thereto; two energized power taps were daisy chained together. A 3-foot, Power Source Model PS600 power tap was plugged into a 6-foot, Tripp Lite 6-place, Model E128811 power tap. This condition exposed employees to fire hazard.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 1 4 instances 24 exposed
Issued
May 3, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.  Building 26, on or about 13 April 2017 and times prior thereto; four instances were noted where electrical panels were obstructed:       a. Receiving area, a cart with miscellaneous items and boxes were stored front of electrical panel labeled 2LB, impeding access.       b. Receiving area, a small refrigerator, file cabinet, microwave, and miscellaneous items were stored in front of electrical panel labeled TT21.       c. Sporting good sales area, two electrical panels, labeled 2LA and 2HA had items stored in front of them impeding access. A portable stand with electronic equipment was stored in front of panel labeled 2HA. A stool was stored in front of panel labeled 2LA.  This condition exposed employees to an electrical shock and electrical burn hazard.
Recent events (1)
  • — Z (S) $0

1904.32 A04

Other-than-serious 1 instance 24 exposed
Issued
May 3, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30.  Building 26, on or about 13 April 2017 and times prior thereto; The employer did not post the Annual Summary OSHA Form 300A for calendar year 2016. This condition leads to inaccurate reporting of injuries and illnesses.
Recent events (1)
  • — Z (O) $0

1904.40 A

Other-than-serious 3 instances 24 exposed
Issued
May 3, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.  Building 26, Administrative office; on or about 13 April 2017 and times prior; the employer did not provide the OSHA Form 300A  Summary of Work-related Injuries and Illness and OSHA Form 300 Log of Work-Related Injury and Illness Logs for 2014, 2015, and 2016 within four business hours.        Instance (a) For year 2014, OSHA Form 300 and 300A or its equivalent was not provided.             Instance (b) For year 2015, OSHA Form 300 and 300A or its equivalent was not provided.       Instance (c) For year 2016, OSHA Form 300 and 300A or its equivalent was not provided.   This condition leads to delays in collecting of injury and illnesses data.
Recent events (1)
  • — Z (O) $0

1910.22 A01

Other-than-serious 1 instance 3 exposed
Issued
May 3, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition.  Building 26, warehouse area; on or about 13 April 2017 and times prior, the employer did not ensure that the work areas were clean and orderly. Warehouse area had numerous items loosely scattered on the floor impeding the walking and working surface. This condition exposed employees to a tripping hazard.
Recent events (1)
  • — Z (O) $0

1910.101 B

Other-than-serious 1 instance 3 exposed
Issued
May 3, 2017
Abate by
Jun 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6.  Building 26, adjacent to registrar counter, on or about 13 April 2017 and times prior thereto; a compressed gas cylinder containing helium was not secured. This condition exposed employees to a struck by hazard.
Recent events (1)
  • — Z (O) $0

View Coast Guard Exchange's full OSHA safety record →