Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: QVEST SANITATION LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of QVEST SANITATION LLC in MONOGRAM FOODS 300 MOORE RD., PLOVER, WI 54467 (NAICS 561720). OSHA activity number 342257193.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Qvest Sanitation LLC for free Get an email when a new federal OSHA severe-injury report for Qvest Sanitation LLC is published. One employer, no account, unsubscribe in one click.
Site address
MONOGRAM FOODS 300 MOORE RD.
City
PLOVER
State
WI
ZIP
54467
Mailing
P.O. BOX 436, GUYMON, OK 73942
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561720
Employees
18
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 18 exposed
Issued
Aug 16, 2017
Abate by
Sep 14, 2017
Penalty
Initial $8,873 · Current $5,000 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    The employer did not develop and implement an energy control program consisting of energy control procedures, employee training, and periodic inspections for employees engaging in cleaning and sanitation activities on equipment located at 300 Moore Rd. Plover, WI 54467.
Recent events (2)
  • · I (S) $5000
  • · Z (S) $8873

1910.147 C04 II

Serious Gravity 10 1 instance 18 exposed
Issued
Aug 16, 2017
Abate by
Sep 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  The energy control procedure outlined in page nine of the employee manual did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance when employees were performing cleaning and sanitation activities on equipment located at 300 Moore Rd. Plover, WI 54467.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 D

Serious Gravity 10 1 instance 18 exposed
Issued
Aug 16, 2017
Abate by
Sep 14, 2017
Penalty
Initial $8,873 · Current $5,000 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    On or about April 10, 2017, an employee was exposed to the ingoing nip point between the rotating drum and the doctor blade while cleaning an Idaho Steel Nex-Gem potato extruder located at 300 Moore Rd. Plover, WI 54467.  The employer did not ensure employees implemented energy control application steps prior to them engaging in cleaning and sanitation activities of the extruder.  The machine was not deenergized prior to cleaning and sanitizing of the drum area of the extruder.      As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing and maintenance hazards.
Recent events (2)
  • · I (S) $5000
  • · Z (S) $8873

View Qvest Sanitation LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342257193.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.