PLOVER, WI ·
OSHA Inspection: QVEST SANITATION LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of QVEST SANITATION LLC in MONOGRAM FOODS 300 MOORE RD., PLOVER, WI 54467 (NAICS 561720). OSHA activity number 342257193.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QVEST SANITATION LLC
- Site address
- MONOGRAM FOODS 300 MOORE RD.
- City
- PLOVER
- State
- WI
- ZIP
- 54467
- Mailing
- P.O. BOX 436, GUYMON, OK 73942
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561720
- Employees
- 18
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C01
- Issued
- Aug 16, 2017
- Abate by
- Sep 14, 2017
- Penalty
- Initial $8,873 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. The employer did not develop and implement an energy control program consisting of energy control procedures, employee training, and periodic inspections for employees engaging in cleaning and sanitation activities on equipment located at 300 Moore Rd. Plover, WI 54467.
Recent events (2)
- · I (S) $5000
- · Z (S) $8873
1910.147 C04 II
- Issued
- Aug 16, 2017
- Abate by
- Sep 14, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): The energy control procedure outlined in page nine of the employee manual did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance when employees were performing cleaning and sanitation activities on equipment located at 300 Moore Rd. Plover, WI 54467.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 D
- Issued
- Aug 16, 2017
- Abate by
- Sep 14, 2017
- Penalty
- Initial $8,873 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about April 10, 2017, an employee was exposed to the ingoing nip point between the rotating drum and the doctor blade while cleaning an Idaho Steel Nex-Gem potato extruder located at 300 Moore Rd. Plover, WI 54467. The employer did not ensure employees implemented energy control application steps prior to them engaging in cleaning and sanitation activities of the extruder. The machine was not deenergized prior to cleaning and sanitizing of the drum area of the extruder. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing and maintenance hazards.
Recent events (2)
- · I (S) $5000
- · Z (S) $8873
More inspections at Qvest Sanitation LLC
View Qvest Sanitation LLC's full OSHA safety record →
More inspections in this industry (NAICS 561720)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342257193.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.