Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOSE MASONRY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE MASONRY, LLC in 5745 SPENCER TRACE, LIBERTY TOWNSHIP, OH 45044 (NAICS 238140). OSHA activity number 342266129.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jose Masonry, LLC — free Get an email when a new federal OSHA severe-injury report for Jose Masonry, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE MASONRY, LLC
Site address
5745 SPENCER TRACE
City
LIBERTY TOWNSHIP
State
OH
ZIP
45044
Mailing
5448 GOLDEN CASCADE DR., DUBLIN, OH 43016
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 F07

Serious Gravity 10 2 instances 2 exposed
Issued
May 5, 2017
Abate by
Jul 14, 2017
Penalty
Initial $3,803 · Current $750 Reduced
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.     Located along the front area of the residential structure a was three end frame section high self-supported tubular welded frame scaffolding system observed in use which was not erected under the supervision of a competent person to ensure standard guardrails and complete cross bracing systems were erected and utilized.
Recent events (2)
  • — I (S) $750
  • — Z (S) $3803

1926.452 C02

Serious Gravity 10 2 instances 2 exposed
Issued
May 5, 2017
Abate by
Jul 14, 2017
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.    There was an employee observed performing fabricated stone scratch coat installation associated operations from a three end frame section high self-supported tubular welded frame scaffolding system which was not completely protected by cross bracing or equivalent, in that all the cross bracing was missing on the total scaffold system side facing the residential structure exposing the employee to a potential of scaffold system collapse and a fall in excess of 19 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

1926.454 A

Serious Gravity 10 1 instance 2 exposed
Issued
May 5, 2017
Abate by
Jul 14, 2017
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.     Located along the front area of the residential structure a was three end frame section high self-supported tubular welded frame scaffolding system observed in use which erected and used without standard guardrails and complete cross bracing systems by employee(s) who were not trained on the applicable standards or procedures to be followed to minimize scaffolding hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
May 5, 2017
Abate by
May 11, 2017
Penalty
Initial $3,803 · Current $750 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level.      Located along the front area of the residential structure there was an employee observed performing fabricated stone scratch coat installation associated operations from a three end frame section high self-supported tubular welded frame scaffolding system which was not protected by standard guardrails or other conventional fall protection systems exposing the employee to a fall potential in excess of 19 feet.
Recent events (2)
  • — I (S) $750
  • — Z (S) $3803

View Jose Masonry, LLC's full OSHA safety record →