Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BARR CONCRETE

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BARR CONCRETE in 315 H STREET NE, WASHINGTON, DC 20002 (NAICS 236220). OSHA activity number 342272309.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Barr Concrete — free Get an email when a new federal OSHA severe-injury report for Barr Concrete is published. One employer, no account, unsubscribe in one click.
Establishment
BARR CONCRETE
Site address
315 H STREET NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
8420 TERMINAL ROAD, LORTON, VA 22079
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
130
Ownership type
A

1 citation on file for this inspection.

1926.652 E01 II

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 31, 2017
Abate by
Sep 7, 2017
Penalty
Initial $12,548 · Current $12,548
29 CFR 1926.652(e)(1)(ii): Support systems were not installed and removed in a manner that protected employees from cave-ins, structural collapses, or from being struck by members of the support system:  (a) Center of Project, Below Elevation, Prior to Foundation -  The design of the shoring system did not provide protection to the workers when the trench wall collapsed covering the workers with soil and the lag boards, on or about 4/24/2017.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $12548

View Barr Concrete's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342272309.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.