ROUND LAKE, IL —
OSHA Inspection: WEST MACHINE PRODUCTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WEST MACHINE PRODUCTS, INC. in 606 LONG LAKE DR., ROUND LAKE, IL 60073 (NAICS 332710). OSHA activity number 342285046.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WEST MACHINE PRODUCTS, INC.
- Site address
- 606 LONG LAKE DR.
- City
- ROUND LAKE
- State
- IL
- ZIP
- 60073
- Mailing
- 606 LONG LAKE DR., ROUND LAKE, IL 60073
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 20
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C04 II
- Issued
- Jun 6, 2017
- Abate by
- Jul 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) Throughout the facility - During the period between May 1, 2017 and June 1, 2017 employee(s) were exposed to potentially hazardous energy sources when performing service and/or maintenance on the Miyano Bar Lathe (employer asset #004) as the documented energy control procedure (Lockout/Tagout) developed by the employer and located on machine was deficient in that it did not; (1) Outline the scope of the procedure, (2) Describe the intended purpose of the procedure, (3) Describe the means to enforce compliance with the procedure, and (4) Identify the magnitude(s) of energy for all hazardous energy sources. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (O) $0
More inspections at West Machine Products, INC.
View West Machine Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342285046.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.