Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELRINGKLINGER USA, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ELRINGKLINGER USA, INC. in 4961 GOLDEN PARKWAY, BUFORD, GA 30518 (NAICS 336370). OSHA activity number 342290392.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Elringklinger USA, INC. — free Get an email when a new federal OSHA severe-injury report for Elringklinger USA, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4961 GOLDEN PARKWAY
City
BUFORD
State
GA
ZIP
30518
Mailing
4961 GOLDEN PARKWAY, BUFORD, GA 30518
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336370
Employees
360
Ownership type
A

7 citations on file for this inspection.

1910.95 I03

Serious Gravity 5 5 instances 48 exposed
Issued
Oct 31, 2017
Abate by
Sep 25, 2018
Penalty
Initial $9,959 · Current $9,000 Reduced

Hazardous substances 8111

29 CFR 1910.95(i)(3): Employees were not given the opportunity to select their hearing protectors from a variety of suitable hearing protectors provided by the employer:    a) Elringklinger USA, Inc., Buford, GA - In the DMax area, an employee operating the press #6 was exposed to noise at a time weighted average of 90.7 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 450 minutes. Only one type of hearing protection was provided, on or about 5/4/17.    b) Elringklinger USA, Inc., Buford, GA - In the HST3 zone, an employee operating the Ona 67 press was exposed to noise at a time weighted average of 90 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 438 minutes. Only one type of hearing protection was provided, on or about 5/4/17.    c) Elringklinger USA, Inc., Buford, GA - In the DMax area, an employee operating the Hahn/Master cell was exposed to noise at a time weighted average of 88.1 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 432 minutes. Only one type of hearing protection was provided, on or about 5/4/17.    d) Elringklinger USA, Inc., Buford, GA - In the DMax area, an employee operating the press #7 was exposed to noise at a time weighted average of 88.7 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 449 minutes. Only one type of hearing protection was provided, on or about 5/4/17.    e) Elringklinger USA, Inc., Buford, GA - In building #2, PTEF area, an employee operating the lathes was exposed to noise at a projected noise level of 88 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 351minutes. Only one type of hearing protection was provided, on or about 5/4/17.
Recent events (3)
  • — F (S) $9000
  • — C (S) $9959
  • — Z (S) $9959

1910.95 K03 I

Serious Gravity 5 5 instances 48 exposed
Issued
Oct 31, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(k)(3)(i): The employer did not ensure that each employee was informed of the effects of noise on hearing:    a) Elringklinger USA, Inc., Buford, GA - In the DMax area, an employee operating the press #6 was exposed to noise at a time weighted average of 90.7 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 450 minutes. Information about the effects of noise on hearing was not provided, on or about 5/4/17.    b) Elringklinger USA, Inc., Buford, GA - In the HST3 zone, an employee operating the Ona 67 press was exposed to noise at a time weighted average of 90 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 438 minutes. Information about the effects of noise on hearing was not provided, on or about 5/4/17.    c) Elringklinger USA, Inc., Buford, GA - In the DMax area, an employee operating the Hahn/Master cell was exposed to noise at a time weighted average of 88.1 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 432 minutes. Information about the effects of noise on hearing was not provided, on or about 5/4/17.    d) Elringklinger USA, Inc., Buford, GA - In the DMax area, an employee operating the press #7 was exposed to noise at a time weighted average of 88.7 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 449 minutes. Information about the effects of noise on hearing was not provided, on or about 5/4/17.    e) Elringklinger USA, Inc., Buford, GA - In building #2, PTEF area, an employee operating the lathes was exposed to noise at a projected noise level of 88 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 351minutes. Information about the effects of noise on hearing was not provided, on or about 5/4/17.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.95 K03 II

Serious Gravity 5 5 instances 48 exposed
Issued
Oct 31, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(k)(3)(ii): The employer did not ensure that each employee was informed of the purpose of hearing protectors, the advantages, disadvantages, and attenuation of various types, and instructions on selection, fitting, use and care:  a) Elringklinger USA, Inc., Buford, GA - In the DMax area, an employee operating the press #6 was exposed to noise at a time weighted average of 90.7 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 450 minutes. Noise training to include information about the purpose of hearing protectors, the advantages, disadvantages, and attenuation of various types, and instructions on selection, fitting, use and care was not provided, on or about 5/4/17.  b) Elringklinger USA, Inc., Buford, GA - In the HST3 zone, an employee operating the Ona 67 press was exposed to noise at a time weighted average of 90 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 438 minutes. Noise training to include information about the purpose of hearing protectors, the advantages, disadvantages, and attenuation of various types, and instructions on selection, fitting, use and care was not provided, on or about 5/4/17.  c) Elringklinger USA, Inc., Buford, GA - In the DMax area, an employee operating the Hahn/Master cell was exposed to noise at a time weighted average of 88.1 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 432 minutes. Noise training to include information about the purpose of hearing protectors, the advantages, disadvantages, and attenuation of various types, and instructions on selection, fitting, use and care was not provided, on or about 5/4/17.  d) Elringklinger USA, Inc., Buford, GA - In the DMax area, an employee operating the press #7 was exposed to noise at a time weighted average of 88.7 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 449 minutes. Noise training to include information about the purpose of hearing protectors, the advantages, disadvantages, and attenuation of various types, and instructions on selection, fitting, use and care was not provided, on or about 5/4/17.  e) Elringklinger USA, Inc., Buford, GA - In building #2, PTEF area, an employee operating the lathes was exposed to noise at a projected noise level of 88 dBA, exceeding the action level of 85 dBA. The exposure was derived from a sample taken over 351minutes. Noise training to include information about the purpose of hearing protectors, the advantages, disadvantages, and attenuation of various types, and instructions on selection, fitting, use and care was not provided, on or about 5/4/17.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1200 F08

Serious Gravity 1 1 instance 10 exposed
Issued
Oct 31, 2017
Abate by
Sep 25, 2018
Penalty
Initial $5,975 · Current $5,000 Reduced
29 CFR 1910.1200(f)(8): The employer did not ensure that portable containers into which hazardous chemicals were  transferred from labeled containers and which were not intended for the immediate use of the person doing the transfer, were properly labeled.    Elringklinger USA, Inc., Buford, GA - Employees used different oils and lubricants to spray dies and equipment. The spray bottles are used by all operators. Spray bottles containing hydraulic oil, WD 40 and Newform 11 that did not have any label, were observed, on or about 5/3/17.
Recent events (3)
  • — F (S) $5000
  • — C (S) $5975
  • — Z (S) $5975

1910.1200 H03 IV

Serious Gravity 1 1 instance 60 exposed
Issued
Oct 31, 2017
Abate by
Sep 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv): Training provided by the employer did not include the details of the employer's hazard communication program, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information.    Elringklinger USA, Inc., Buford, GA - Employees used chemicals such as but not limited to, Mineral Spirits, Neuform 811, Drosera MS 68 Lubricant, Simple Green, WD 40 and Hydraulic Oil for lubrication and cleaning. Information about safety data sheets and how to use the information in them was not provided, on or about 5/2/17.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Oct 31, 2017
Abate by
Sep 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested whenever a different respirator facepiece (size, style, model or make) was used:    Elringklinger USA, Inc., Buford, GA - In the mixing room, the mixer was assigned and required to use a half mask, tight fitting respirator while cleaning drums. Fit test for the half mask respirator was not performed, on or about 5/2/17.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.134 K05

Other-than-serious 1 instance 1 exposed
Issued
Oct 31, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(5): Respiratory protection retraining was not conducted annually:  Elringklinger USA, Inc., Buford, GA - In the mixing room, the mixer was assigned and required to use a half mask and full face tight fitting respirator while cleaning drums and mixing solutions containing ammonia. Annual retraining on the use and care of respirator was not conducted, on or about 5/2/17.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Elringklinger USA, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342290392.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.