LITTLETON, CO —
OSHA Inspection: PLUM CREEK PRECAST COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PLUM CREEK PRECAST COMPANY in 9160 N MOORE ROAD, LITTLETON, CO 80125 (NAICS 327390). OSHA activity number 342291051.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PLUM CREEK PRECAST COMPANY
- Site address
- 9160 N MOORE ROAD
- City
- LITTLETON
- State
- CO
- ZIP
- 80125
- Mailing
- 9160 N MOORE ROAD, LITTLETON, CO 80125
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 35
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.213 I01
- Issued
- Jun 15, 2017
- Abate by
- Jun 27, 2017
- Penalty
- Initial $6,338 · Current $6,338
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: (a) On or about April 27, 2017, and at times prior, employees were exposed to laceration injuries while using a Ramco band saw, located in the shop area, with the guard in the fully retracted position. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $6338
- — Z (S) $6338
1910.215 B09
- Issued
- Jun 15, 2017
- Abate by
- Jun 27, 2017
- Penalty
- Initial $5,070 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The guard for an abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: (a) On or about April 27, 2017, and at times prior, the employer exposed employees in the shop area to struck-by hazards due to the Dayton 8" bench grinder missing a tongue guard on the grinder wheel. (b) On or about April 27, 2017, and at times prior, the employer exposed employees in the shop area to struck-by hazards due to the Westward 6" bench grinder tongue guard exceeding one fourth inch. Abatement Note: Abatement certification and documentation are required for these items (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $2500
- — Z (S) $5070
1910.147 C04 I
- Issued
- Jun 15, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about May 5, 2017, and at times prior, the employer did not ensure energy control procedures had been established and implemented so as to protect employees exposed to hazards associated with the unexpected energizing, startup or release of stored energy for the cement mixers such as, but not limited to the McNeilus 10 1/2" cubic yard mixer. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Jun 15, 2017
- Abate by
- Jun 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about April 27, 2017, and at times prior, the employer did not maintain a clear distance of three feet in front of the circuit breaker panel, located in the shop area, in order to provide access for emergency maintenance. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Jun 15, 2017
- Abate by
- Jun 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) On or about April 27, 2017, and at times prior, employees were exposed to electrical hazards in that the light switch receptacle, located in the concrete test area, was missing a faceplate. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Plum Creek Precast Company
View Plum Creek Precast Company's full OSHA safety record →
More inspections in this industry (NAICS 327390)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342291051.