GEORGETOWN, MA —
OSHA Inspection: M J INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of M J INDUSTRIES, INC. in 4 CARLETON DRIVE, GEORGETOWN, MA 01833 (NAICS 337127). OSHA activity number 342291408.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M J INDUSTRIES, INC.
- Site address
- 4 CARLETON DRIVE
- City
- GEORGETOWN
- State
- MA
- ZIP
- 01833
- Mailing
- 4 CARLETON DRIVE P.O. BOX 259, GEORGETOWN, MA 01833
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337127
- Employees
- 11
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.107 L01
- Issued
- Jun 6, 2017
- Abate by
- Jul 10, 2017
- Penalty
- Initial $3,622 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.107(l)(1): Electrical equipment and other sources of ignition did not conform to the requirements of paragraphs (c)(1)(i)-(iv), (8) and (9)(i) of this section and subpart S of this part: (a) Location - 4 Carleton Drive, Georgetown, MA: On or about 5/2/2017, electrical equipment including an emergency light, a junction box, and an outlet located in close enough proximity to a powder coating operation utilizing combustible powder for the powder to accumulate on them were not intrinsically safe, approved for a Class II, Division 2, or safe for a Class II, Division 2 location.
Recent events (2)
- — I (S) $1800
- — Z (S) $3622
1910.107 L04 I
- Issued
- Jun 6, 2017
- Abate by
- Jul 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(l)(4)(i): All areas were not kept free of the accumulation of powder coating dust: (a) Location - 4 Carleton Drive, Georgetown, MA: On or about 4/28/2017, the area used for storage immediately adjacent to the powder coating booth and the area behind the industrial oven were not kept free of accumulations of combustible powder coating dust.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Jun 6, 2017
- Abate by
- Jul 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Location - 4 Carleton Drive, Georgetown, MA: On or about 5/2/2017, the junction box installed in conjunction with the emergency light by the powder coating booth is missing a knockout.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at M J Industries, INC.
View M J Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337127)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342291408.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.