Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LARIOS MASONRY, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LARIOS MASONRY, LLC. in 2612 LAGO NICOLA LN., LEAGUE CITY, TX 77573 (NAICS 238140). OSHA activity number 342294931.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Larios Masonry, LLC. — free Get an email when a new federal OSHA severe-injury report for Larios Masonry, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
2612 LAGO NICOLA LN.
City
LEAGUE CITY
State
TX
ZIP
77573
Mailing
23973 ORCHID BEE LANE, NEW CANEY, TX 77357
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.451 F03

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 6, 2017
Abate by
Jul 25, 2017
Penalty
Initial $3,803 · Current $2,271 Reduced
29 CFR 1926.451(f)(3): Scaffold and scaffold components were not inspected for visible defects by a competent person before each workshift and after any occurrence which could affect a scaffold's structural integrity:  a) At the job site the fabricated welded frame scaffolding was not inspected by a competent person.
Recent events (2)
  • — I (S) $2271
  • — Z (S) $3803

1926.451 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 6, 2017
Abate by
Jul 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames and uprights were not bear on base plates and mud sills or other adequate firm foundation:  a) At the job site the mason tubular scaffold had the legs missing the base plates and the mud sills.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 6, 2017
Abate by
Jul 25, 2017
Penalty
Initial $3,803 · Current $2,271 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolding was not fully planked or decked:  a) At the job site the fabricated frame scaffolding was not fully planked.
Recent events (2)
  • — I (S) $2271
  • — Z (S) $3803

1926.451 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 6, 2017
Abate by
Jul 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): Where scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers, stairway-type ladders, ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used for access:  a) At the job site the fabricated frame scaffolding did not had a ladder installed for access and or egress.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 6, 2017
Abate by
Jul 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  a) At the job site the fabricated frame scaffolding did not had guardrails installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 H02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 6, 2017
Abate by
Jul 25, 2017
Penalty
Initial $1,630 · Current $978 Reduced
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:  a) At the job site the mason tubular scaffold in use did not had toe boards installed.
Recent events (2)
  • — I (S) $978
  • — Z (S) $1630

View Larios Masonry, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342294931.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.