FAIRFIELD, ID —
OSHA Inspection: EARTH & STRUCTURE INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EARTH & STRUCTURE INC in 1000 E HWY 20, FAIRFIELD, ID 83327 (NAICS 332312). OSHA activity number 342295771.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EARTH & STRUCTURE INC
- Site address
- 1000 E HWY 20
- City
- FAIRFIELD
- State
- ID
- ZIP
- 83327
- Mailing
- 1000 E HWY 20, FAIRFIELD, ID 83327
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 20
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.28 B02 I
- Issued
- Jun 12, 2017
- Abate by
- Jul 7, 2017
- Penalty
- Initial $3,622 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.28(b)(2)(i): The employer did not ensure employees in a hoist area were protected from falling 4 feet or more to a lower level. (a) Shop: On or about May 9, 2017, and at times prior thereto, employees access the material storage area and are exposed to an approximate 12 foot fall hazard to a concrete floor. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $2000
- — Z (S) $3622
1910.110 D10
- Issued
- Jun 12, 2017
- Abate by
- Jul 7, 2017
- Penalty
- Initial $3,622 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.110(d)(10): Precautions were not taken to prevent damage to LP gas system(s) from vehicular traffic: (a) Yard: On or about May 9, 2017, and at times prior thereto, tracks observed from a Gehl rough terrain were measured approximately 14 feet away from an unprotected 1000 lb. propane tank. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $2000
- — Z (S) $3622
1910.212 A03 II
- Issued
- Jun 12, 2017
- Abate by
- Sep 1, 2017
- Penalty
- Initial $2,897 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machine whose operation exposed an employee to injury, was not guarded: a) Shop: On or about May 9, 2017 and at times prior thereto; A Drill Press did not have a guard affixed to the point of operation that would prevent an operators fingers or hand from being caught in the drill attachment. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $1000
- — Z (S) $2897
1910.212 B
- Issued
- Jun 12, 2017
- Abate by
- Jul 7, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) On or about May 9, 2017, and at times prior thereto, a Drill Press not equipped with an identification plate with make and/or model, but the motor had a serial number JD 031448. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Jun 12, 2017
- Abate by
- Sep 1, 2017
- Penalty
- Initial $2,897 · Current $1,600 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling: a) Shop: On or about May 9, 2017, and at times prior thereto, a flexible cord was used to provide power to a Drill Press. b) Yard: On or about May 9, 2017, and at times prior thereto, flexible cords were used with the junction box for the Airless Sprayer. c) Arc Light Dynamics Pro 12000: On or about May 9, 2017, and at times prior thereto, a metal junction box was found on the floor and utilized to power the computer for the plasma table. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $1600
- — Z (S) $2897
1910.305 B01 II
- Issued
- Jun 12, 2017
- Abate by
- Sep 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed. a) Shop: On or about May 9, 2017 and at times prior thereto a knockout plug was missing from a 4 way junction box left on the floor. b) Mechanical Bay: On or about May 9, 2017 and at times prior thereto a knockout plug was missing from a 2 way junction box in use providing temporary power to the Drill Press. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Jun 12, 2017
- Abate by
- Sep 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: a) Mechanical Bay: On or about May 9, 2017, and at times prior thereto a 2 way junction box was in use providing temporary power to the Drill Press. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Jun 12, 2017
- Abate by
- Sep 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Yard: On or about May 9, 2017, and at times prior thereto, Airless paint sprayer. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 I
- Issued
- Jun 12, 2017
- Abate by
- Sep 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). a) Shop/Yard: On or about May 9, 2017 and at times prior thereto, the employer did not implement necessary inspections prior to use, defects found included but were not limited to, junction boxes found damaged and not in use per manufacturer listed and labeled requirements, flexible cords in need of strain relief, flexible cords substituting for fixed wiring. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Earth & Structure INC
View Earth & Structure INC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342295771.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.