OSHA Inspection: MCV CONTRACTING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MCV CONTRACTING, INC. in 300 SE 3RD ST, MIAMI, FL 33133 (NAICS 238120). OSHA activity number 342300076.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MCV Contracting, INC. — free Get an email when a new federal OSHA severe-injury report for MCV Contracting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
300 SE 3RD ST
City
MIAMI
State
FL
ZIP
33133
Mailing
13950 NW 107TH AVE., HIALEAH GARDENS, FL 33018
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
95
Ownership type
A

3 citations on file for this inspection.

1926.404 B01 I

Other-than-serious 2 instances 2 exposed
Issued
Oct 18, 2017
Abate by
Oct 25, 2017
Penalty
Initial $7,243 · Current $3,622 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.       On or about 5/3/2017, at Deck level #39 of the above addressed worksite, the employer had not protected employees from an electrical hazard as evidenced by, among other conditions; a portable saw (Skil, Model SPT2ZW, Serial #505006592) which lacked a ground prong was energized from a non-functioning ground fault circuit interrupter; equipment found to be defective was not tagged to prevent its use and/or daily inspections of equipment connected by cord and plug were not made prior to usage, etc.
Recent events (2)
  • — I (O) $3621.5
  • — Z (S) $7243

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Oct 18, 2017
Abate by
Oct 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous    On or about 5/3/2017, at Deck level #39 of the above addressed worksite, employees were exposed to an electrical hazard while cutting wood with a portable saw (Skil, Model SPT2ZW, Serial #505006592) that lacked a ground prong on its attachment plug.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.701 B

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 18, 2017
Abate by
Oct 25, 2017
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement:    On or about 5/3/2017, at Deck level #36 of the above addressed worksite, an employee was exposed to an impalement hazard while setting a deck over an elevator landing which had unguarded rebars on both sides.