Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OWENS CORNING INSULATING SYSTEMS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of OWENS CORNING INSULATING SYSTEMS, LLC in 1277 FEURA BUSH RD., FEURA BUSH, NY 12067 (NAICS 327993). OSHA activity number 342302544.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Owens Corning Insulating Systems, LLC — free Get an email when a new federal OSHA severe-injury report for Owens Corning Insulating Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1277 FEURA BUSH RD.
City
FEURA BUSH
State
NY
ZIP
12067
Mailing
1277 FEURA BUSH RD., FEURA BUSH, NY 12067
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327993
Employees
269
Ownership type
A

5 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 13, 2017
Abate by
Apr 3, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms and walking-working surfaces were not kept clean, orderly and in sanitary condition.    A) Repack Area - On or about May 2, 2017, the floor, catwalks, and other walking working surfaces around the Shredder were obstructed by piles of scrap insulation.
Recent events (3)
  • — F (S) $9959
  • — C (S) $9959
  • — Z (S) $9959

1910.22 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 13, 2017
Abate by
Apr 3, 2018
Penalty
Initial $9,959 · Current $0 Reduced
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces were inspected, regularly and as necessary, and maintained in a safe condition:    A) Repack Area - On or about May 2, 2017, the employer failed to clear scrap insulation that was blocking exits, electrical equipment, floors, catwalks, and other walking working surfaces around the Shredder.
Recent events (3)
  • — F (S) $0
  • — C (S) $9959
  • — Z (S) $9959

1910.37 A03

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 13, 2017
Abate by
Apr 3, 2018
Penalty
Initial $9,959 · Current $0 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    A) Repack Area - On or about May 2, 2017, the exit door to the Compactor Room was blocked by a large pile of scrap insulation.
Recent events (3)
  • — F (S) $0
  • — C (S) $9959
  • — Z (S) $9959

1910.303 G01 I A

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 13, 2017
Abate by
Apr 3, 2018
Penalty
Initial $7,967 · Current $0 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:    A) Repack Area - On or about May 2, 2017, the area in front of electrical equipment including but not limited to: DM-1/Repack MCC, and Repack MCC-55-D-700, was not kept clear.  Labeling on the equipment indicated that it was 480 V.  Per Table S-1, this equipment needed 36 inches of clearance in front of the equipment.  Scrap insulation was piled in front of the equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $7967
  • — Z (S) $7967

1910.1200 F06 II

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 13, 2017
Penalty
Initial $5,975 · Current $5,975
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical    A) Worksite - On or about May 2, 2017, the outdoor diesel tank, PBS-10, was not labeled as to the hazards of the chemical, diesel fuel.
Recent events (3)
  • — F (S) $5975
  • — C (S) $5975
  • — Z (S) $5975

View Owens Corning Insulating Systems, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342302544.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.